نتایج جستجو برای: 30 gauge needle

تعداد نتایج: 599569  

Journal: :Stroke 1970
L M Dyll J W Dyll R J Speer

Abitract: Retrieval of a Thrombus Attached to a Cournand Needle • Upon completion of a carotid angiogram, a clot of platelets, leukocytes, erythrocytes and fibrin was found attached to a No. 18 gauge Cournand needle. The chance retrieval of this thrombus establishes the occurrence of thrombus formation on angiographic needles. Such thrombi could be the source of some post-angiographic infarctio...

Journal: :Journal of magnetic resonance imaging : JMRI 2007
Philip Blumenfeld Nobuhiko Hata Simon DiMaio Kelly Zou Steven Haker Gabor Fichtinger Clare M C Tempany

PURPOSE To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. MATERIALS AND METHODS A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intrapr...

Journal: :Cell transplantation 2006
András M Komáromy Signe E Varner Eugene de Juan Gregory M Acland Gustavo D Aguirre

The use of a new subretinal injection device (RetinaJect Subretinal Cannula, SurModics, Inc., Eden Prairie, MN) to access the subretinal space in the canine model was evaluated. Subretinal injections were performed in 33 mongrel dogs between 2 and 52 months of age (median = 9 months). In 5 normal dogs the injection of 150 microl saline or India ink occurred by using a conventional subretinal in...

2017
Priscilla van Riet Paolo Giorgio Arcidiacono Mariachiara Petrone Emanuele Dabizzi Nam Quoc Nguyen Masayuki Kitano Kenneth Chang Schalk van der Merwe Marco J. Bruno Djuna L. Cahen Alberto Larghi Julio Iglesias-Garcia Marc Giovannini Erwin Santo Francisco Baldaque Silva Juan Carlos Bucobo Marie Robert Adebowale Adeniran Romulo Celli Harry Aslanian James Farrell

S12 ENDOSCOPIC ULTRASOUND / VOLUME 6 / SUPPLEMENT 1 / AUGUST 2017 diagnostic value of specimens obtained with the new 20-gauge ProCore biopsy needle. Follow-up data are required to confirm the diagnostic accuracy of this agreement. DOI: 10.4103/2303-9027.212302

2014
Maria Trapasso Aniello Veneroso

SUMMARY Sometimes, after local anesthetic injection for surgical procedures of the upper eyelid, it is possible to observe superficial preseptal hematomas or excessive lid swelling that may distort the tissues and obscure surgical landmarks. We present a technique to perform local anesthesia of the upper eyelids, using a 27-gauge needle and a 26-gauge filling cannula, that may decrease the inci...

Journal: :AJR. American journal of roentgenology 1989
J L Vezina S Fontaine J Laperriere

Postmyelography headaches are produced mostly by CSF leakage at the dural puncture site and are therefore largely dependent on the size of the needle used. Our study of 300 consecutive outpatients who had lumbar myelograms performed with 25- and 26-gauge spinal needles shows that the procedure has become virtually innocuous. We recommend that 26-gauge spinal needles be widely adopted as the sta...

Journal: :Archives of The Medicine and Case Reports 2022

Tension pneumothorax can occur as a potentially life threatening complication of chest trauma. is commonly treated with needle decompression, both the 2nd intercostal space in midclavicular line and 4th/5th anterior axillary. A 45 years old man came to our emergency department after blunt injury presenting tension unstable hemodynamic decompression using 14 gauge (4.5 cm) cannula at mid clavicu...

2013
Ji Young Bang Shyam Varadarajulu

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is routinely performed for establishing tissue diagnosis in patients with gastrointestinal tumors. The concept of delivering chemotherapy based on molecular markers and the ability to establish a reliable diagnosis in lieu of an onsite cytopathologist has fuelled the recent trend in procuring core tissue by means of EUS-guided fine n...

2013
Angelo Carpi Giuseppe Rossi Andrea Nicolini Giorgio Iervasi Matteo Russo Jeffrey Mechanick

Thyroid large needle aspiration biopsy is disregarded because it is thought to be associated with pain. This is in contrast with our 32 years long experience. We surveyed reports of pain in patients examined with fine needle aspiration biopsy (78, 87.2% women, mean age 59 years) or FNAB+large needle aspiration biopsy (48, 87.5% women, mean age 60 years). Each patient was questioned regarding a)...

2006

proportionating system was dismantled and a gas leak found in the Cambridge Bourdon tube type dialysate temperature gauge which caused the needle pointer to register about 20'C too low. The fault had come on over a period of time and, unfortunately, it had been assumed that the Cambridge gauge was indicating the true dialysate temperature. Therefore the back-up temperature alarm system and the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید