نتایج جستجو برای: 111in oxine
تعداد نتایج: 1159 فیلتر نتایج به سال:
the high expression of somatostatin receptors in many tumours, have made receptor scintigraphy with 111in-dtpa-octreotide a widly used procedure in nuclear medicine. despite its clinical success, some limitation and drawbacks of radiolabelling with 111in remain, especially those concerned with the cost, availability and physical decay properties of this radionuclide. 99mtc-edda/hynic-tyr3-toc w...
A novel Ti/111In-heterometallic radiotheranostic along with non-radioactive Ti/In, Ti/Lu, and Ti/Y analogues has been reported, thanks to the design of a challenging synthesis of the first titanocene-DOTA ligand. The corresponding titanocene-BODIPY complex was developed for in vitro tracking by optical imaging. The different complexes were characterized and their antiproliferative properties we...
PURPOSE The present study aims at developing and evaluating an urea-based prostate specific membrane antigen (PSMA) inhibitor suitable for labeling with 111In for SPECT and intraoperative applications as well as 68Ga and 64Cu for PET imaging. METHODS The PSMA-based inhibitor-lysine-urea-glutamate-coupled to the spacer Phe-Phe-D-Lys(suberoyl) and functionalized with the enantiomerically pure p...
UNLABELLED Imaging with radiolabeled somatostatin (SST) analogs has recently been established for the localization of various human SST receptor (hsstr)-positive tumors, including neuroendocrine tumors, lymphomas, and non-small cell lung cancer (NSCLC). METHODS 111In-1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic acid-lanreotide (DOTA-LAN) scintigraphy (150 MBq; 7 nmol per patient) wa...
To study the effects of antithrombotic therapy in experimental stroke, we have characterized a baboon model of acute cerebrovascular thrombosis. In this model an inflatable silastic balloon cuff has been implanted by transorbital approach around the right middle cerebral artery (MCA), proximal to the take-off of the lenticulostriate arteries (LSA). Inflation of the balloon for 3 hours in six an...
A human B-cell lymphoma xenograft model was used to test whether the administration of unlabeled MoAb prior to injection of radiolabeled monoclonal antibody (MoAb) improves delivery of the radiolabeled MoAb to tumor prior to testing in clinical radioimmunotherapy trials. The anti-B1/CD20 pan-B-cell MoAb reactive with human B-cell lymphomas and leukemias but not reactive with mouse B-cells was u...
d-Glucosamine (DG) was conjugated to a core-cross linked polymeric micelle (CCPM) system equipped with both a near-infrared fluorophore (NIRF) and a gamma emitter (111In). The resultant nano-scale tumor-targeting imaging tracer, 111In-DG-NIRF-CCPM, selectively accumulated in a human epithelial carcinoma A-431 xenograft model in mice. At 24 hrs post injection, the tumor uptake was 2.62 ± 0.80 % ...
Thrombocytopenia is a common occurrence (20%) in sick neonates. but the causes have not been well studied. In this report we demonstrate that thrombocytopenia in the neonate is characterized by increased platelet destruction as shown by shortened homologous “In-oxine-labeled platelet life spans. Thirty-one prospectively studied thrombocytopenic neonates were investigated by measuring the “In-la...
large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. therefore, radiation unwanted dose is created in kidney. as a result, exact calculation of prescribed radiopharmaceuticals amount is important. monte carlo method is used for simulation of radiation transport in body due to random nature of radiation. in this research, for the first time...
location of focal infectious roc’2 As opposed to galhum, accumulation in normal bowel does not signfficantly affect imaging ofthe abdomen and pelvis. It can also identify extra-abdominal sites ofinfection as well; in one study, three patients had pneumonitis detected prior to the appearance of an abnormal chest roentgenogram 13 The “In-WBC scanning is performed by obtaining a leukocyte-rich fra...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید