نتایج جستجو برای: wall

تعداد نتایج: 169225  

Journal: :گوارش 0
afshin mohamadi mehdi mohamadifar masud sadredini ramin behrozian

background: there are two kinds of ascites, cirrhotic and malignant. the conventional diagnostic method to differentiate them is paracentesis. this is an invasive and time consuming method. however, ultrasonography is an easy and available method to provide valuable results in a short period of time. the aim of this study was to evaluate gallbladder wall thickness in differentiating cirrhotic a...

Journal: :international journal of environmental research 2011
p. wang d. zhao w. wang h. mu g. cai

his investigation was carried out to reveal the impact of solar radiation on wind flow structure and pollutant dispersion in an urban street canyon of aspect ratio of one using the computational fluid dynamic (cfd) technique. the simulation results (velocity and concentration data) show that heating from building wall surfaces and ground lead to strong buoyancy forces as the air is heated by th...

Journal: :مکانیک سیالات و آیرودینامیک 0
علی عباس¬نژاد محمود نوروزی زکیه طالبی

the purpose of this research is to numerically investigate the interaction of pulsatile flow of blood with an axisymmetric artery in various percentages of stenosis. the carreau non-newtonian model and the generalized maxwell rheological model were used to model the blood fluid and the viscoelastic wall of arterial, respectively. the innovation of the present research is modeling of viscoelasti...

Journal: :journal of computational applied mechanics 0
hadi ramin center of excellence in design and optimization of energy systems, school of mechanical engineering, college of engineering, university of tehran, tehran, iran pedram hanafizadeh center of excellence in design and optimization of energy systems, school of mechanical engineering, college of engineering, university of tehran, tehran, iran mohammad ali akhavanbehabadi center of excellence in design and optimization of energy systems, school of mechanical engineering, college of engineering, university of tehran, tehran, iran

in this paper, dynamic transient method and conventional degree-hours method (static) have been compared to estimate heating and cooling loads of building’s wall. all main wall surfaces of various orientations, i.e.south, west, east, north, and horizontal are considered in the climate of tehran, iran. in this study, a conventional wall structure, which is comprisedconcrete as main wall material...

Journal: :journal of minimally invasive surgical sciences 0
abdolreza pazouki minimally invasive surgery research center, iran university of medical sciences, tehran, ir iran zahra omrani department of general surgery, rasul hospital, iran university of medical sciences, tehran, ir iran; department of general surgery, rasool hospital, iran university of medical sciences, tehran, ir iran. tel: +98-2164352215, fax: +98-2164352215 roozbeh cheraghali department of general surgery, rasul hospital, iran university of medical sciences, tehran, ir iran seyed hamze musavi department of general surgery, rasul hospital, iran university of medical sciences, tehran, ir iran

conclusions traumatic abdominal wall hernia tawh, although uncommon, is associated with significant rate of morbidity and mortality in cases of delayed diagnosis and intervention. early intervention leads to a significantly better outcome. introduction acute abdominal wall rupture with visceral herniation due to blunt traumas and bowel incarceration or perforation are generally rare phenomena. ...

Journal: :Palestine Exploration Quarterly 1890

An overview of removal and re-entrainment of particles in turbulent flows is presented. The procedure for the direct numerical simulation (DNS) of the Navier-Stokes equation via a pseudospectral method for simulating the instantaneous fluid velocity field is described. Particle removal mechanisms in turbulent flows in a duct are examined and effects of the near-wall coherent eddies on the parti...

Leila Shahryari Mahdi Esfandiari

The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...

Journal: Pollution 2015

Agricultural waste fibers have been found to be suitable as reinforcement in cement-based composites, but studies on oil palm fiber as reinforcement in gypsum-cement wall panels are scarce. A mixture of two equal weights of gypsum and cement, with water-binder ratios of 0.45 and 0.55 were prepared. In each mix a varying percentage of fiber contents of 2%, 3% and 4% by weight of the binders were...

C. R. Suribabu, V. Nandha Kumar,

Optimal design of cantilever reinforced concrete retaining wall can lead considerable cost saving if its involvement in hill road formation and railway line formation is significant.  A study of weight reduction optimization of reinforced cantilever retaining wall subjected to a sloped backfill using Differential Evolution Algorithm (DEA) is carried out in the present research.  The r...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید