.lthough the cornea is very flexible, force must be required to bend it. Goldmann and Schmidt' and Gloster and Perkins following Imbert and Fick have considered bending resistance in applantation tonometry. Friedenwald however, in his studies on Schi0tz tonometry, came to the conclusion that the resistance of the cornea to deformation is negligibly small. The corneal bending forces involved in ...
The importance of endothelial dysfunction in the development and clinical expression of cardiovascular disease is well recognized. Impaired endothelial function has been associated with an increased risk of cardiovascular events. Endothelial function may be evaluated in humans by assessing vasodilation in response to stimuli known to induce the release of nitric oxide. A novel pulse amplitude t...
AIMS To establish the effects of central corneal thickness (CCT) on intraocular pressure (IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the effect of CCT and age on the agreement between IOP measured with the Pascal DCT and Goldmann applanation tonometer (GAT), and to compare the interobserver and intraobserver variation of the DCT with the GAT. METHODS GA...
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes without a history of trabeculectomy but with a history of latanoprost use (Latanoprost group, LG), and 19 nonglaucomatous eyes (Control group, C...
PURPOSE To examine the differences between Goldmann Applanation Tonometry (GAT) and Dynamic Contour Tonometry (DCT) associated with latanoprost use. METHODS Twenty-four eyes (of 24 patients) treated with latanoprost monotherapy (latanoprost group, LG), 11 eyes (of 11 patients) not receiving prostaglandin analogs (nonlatanoprost group, NLG), and 20 eyes of 20 nonglaucomatous patients (control ...
PURPOSE To evaluate whether the pressure phosphene tonometer (PPT) is suitable for self-tonometry in patients with glaucoma or ocular hypertension. METHODS This was a prospective comparative study of 102 eyes of 102 patients with chronic glaucoma or ocular hypertension. Intraocular pressure (IOP) measurements by the Goldmann tonometer (GT) were compared with self-measured readings with the PP...