نتایج جستجو برای: tibial delayed

تعداد نتایج: 116435  

Journal: :Clinical biomechanics 2013
Takahiro Arai Hiroichi Miaki

BACKGROUND Dynamic alignment of "knee-in & toe-out" is a risk factor for anterior cruciate ligament injury and is possibly influenced by static knee alignment, range of tibial rotation and tibial plateau geometry. METHODS Twenty-eight healthy women were classified into valgus, neutral and varus groups based on static alignment of their knees. A 3-dimensional motion analysis was carried out fo...

Journal: :the archives of bone and joint surgery 0
karim z. masrouha infection, open tibial fracture, polymethylmethacrylate, soft tissue defect youssef el-bitar infection, open tibial fracture, polymethylmethacrylate, soft tissue defect marc najjar infection, open tibial fracture, polymethylmethacrylate, soft tissue defect said saghieh infection, open tibial fracture, polymethylmethacrylate, soft tissue defect

the management of soft tissue defects in tibial fractures is essential for limb preservation. current techniques are not without complications and may lead to poor functional outcomes. a salvage method is described using three illustrative cases whereby a combination of flaps and antibiotic-impregnated polymethylmethacrylate beads are employed to fill the bony defect, fight the infection, and p...

2015
Greg A J Robertson Alexander M Wood

Stress fractures in sport are becoming increasing more common, comprising up to 10% of all of sporting injuries. Around 90% of such injuries are located in the lower limb. This articles aims to define the optimal management of lower limb stress fractures in the athlete, with a view to maximise return rates and minimise return times to sport. Treatment planning of this condition is specific to t...

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2003
Keith L Markolf David R McAllister Charles R Young Justin McWilliams Daniel A Oakes

With most posterior cruciate (PCL) reconstruction techniques, the distal end of the graft is fixed within a tibial bone tunnel. Although a surgical goal is to locate this tunnel at the center of the PCL's tibial footprint, errors in medial-lateral tunnel placement of the tibial drill guide are possible because the position of the tip of the guide relative to the PCL's tibial footprint can be di...

2018
Seung Joon Rhee Jae Young Cho Seung Hyeon Jeung Kein Boon Poon Yoon Young Choi Jeung Tak Suh

Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سمنان 1392

in the area of vocabulary teaching and learning although much research has been done, only some of it has led to effective techniques of vocabulary teaching and many language learners still have problem learning vocabulary. the urge behind this study was to investigate three methods of teaching words. the first one was teaching words in context based on a traditional method of teaching that is,...

2014
Suhayl Tafazal Sanjeev S. Madan Farhan Ali Manoj Padman Simone Swift Stanley Jones James A. Fernandes

BACKGROUND The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. METHOD A retrospective analysis of patient records and ra...

2017
Ju-Hyung Yoo Chang-Dong Han Hyun-Cheol Oh Sang-Hoon Park Se-Han Jung Yun-Jae Lee

Purpose This study aims to identify the effectiveness of the medial cortical line for attaining a more accurate tibial component alignment in proximal tibial resection using an extramedullary alignment rod. Materials and Methods The study examined 100 cases of total knee arthroplasty performed from December 2013 to February 2014 in a retrospective manner. On a preoperative anteroposterior (AP...

2015
Yasuaki Nakagawa Shogo Mukai Hiromitsu Yabumoto Eri Tarumi Takashi Nakamura

OBJECTIVES The aim of this study was to examine the relationship between cartilage, ligament, and meniscus degeneration and radiographic alignment in severe varus knee osteoarthritis in order to understand the development of varus knee osteoarthritis. DESIGN Fifty-three patients (71 knees) with primary varus knee osteoarthritis and who underwent total knee arthroplasty were selected for this ...

Journal: :trauma monthly 0
haci bayram tosun department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey; department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey. tel: +90-5334497699, fax: +90-4162231693 ismail agir department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey seyitali gumustas department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey sancar serbest department of orthopaedics and traumatology, faculty of medicine, kirikkale university, kirikkale, turkey abuzer uludag department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey suat celik department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey

conclusions the fixator-assisted lengthening plate technique helps to maintain the stability and alignment at both sides of an osteotomy during tibial elongation. it allows the early removal of the external fixator immediately after lengthening is completed. this technique can be applied in children with open physes and in patients with a narrow medullary canal who are unsuitable for limb lengt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید