نتایج جستجو برای: radioimmunoassay

تعداد نتایج: 9441  

Journal: :Blood 1979
J B Sherwood E Goldwasser

We describe the development of a radioimmunoassay (RIA) for erythropoietin. Antisera were raised in rabbits with an impure human urinary erythropoietin preparation used as immunogen, but with pure human erytropoietin serving as the labeled antigen in the RIA and as a primary standard. The immunoreactivity of erythropoietin is not altered significantly by the mode of labeling with radioiodine, e...

Journal: :Journal of lipid research 1978
I Makino A Tashiro H Hashimoto S Nakagawa I Yoshizawa

A sensitivie and specific radioimmunoassay for the measurement of serum ursodeoxycholic acid has been developed. Ursodeoxycholic acid bound to bovine serum albumin was used as an antigen, and antiserum to this antigen was raised in the rabbit. [11, 12-3h2]Ursodeoxycholic acid was used as the radioactive tracer, and the radioimmunoassay was carried out by the method of Simmonds et al. (1973. Gas...

2006
Dagmar Bartos Robert A. Campbell Frantisek Bartos Donald P. Grettie

Antipolyamine antibodies were produced following im munization of New Zealand white rabbits with thyro globulin spermine conjugate, using multiple-site injection and macrophage-harvesting techniques. The antispermine antibody in a radioimmunoassay system cross-reacted with spermidine (22%), putrescine (1%), diaminopropane (6%), and cadaverine (0.16%). No reaction with L-lysine, orni thine, or h...

Journal: :Clinical chemistry 1984
P Felding

10. Amino N, Nishi K, Nakatani K, et al. Effect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex#{174} F’reeT4). Clin C/tern 29, 321-325 (1983). 11. Stockigt JR, Stevens V, White EL, Barlow JW. “Unbound analog” radioimmunoassay methods for free thyroxin measure the albumin-bound hormone fraction. Clin C/tern 29, 1...

Journal: :Clinical chemistry 1975
A A MacKinney G H Burnett R L Conklin G W Wasson

Digoxin-containing sera from 86 patients were analyzed for this drug by bioassay and radioimmunoassay. Each serum was analyzed in duplicate by six procedures: inhibition of Na+-K+-dependent ATPase and five "kit" radioimmunoassays from four different commercial sources. Mean values for two of the radioimmunoassays differed significantly from those for the bioassay. One radioimmunoassay mean valu...

Journal: :Plant physiology 1983
P Moesta M G Hahn H Grisebach

A radioimmunoassay for glyceollin I, the major phytoalexin produced by soybean (Glycine max [L.] Merr.), has been developed. Antibodies were raised in rabbits against a glyceollin I-bovine serum albumin conjugate. The antisera were used to establish a radioimmunoassay for glyceollin I using [(125)I]glyceollin I as the tracer. A logit plot of a standard concentration series yielded a straight li...

Journal: :Clinical chemistry 1983
R F Butz P G Smith D H Schroeder J W Findlay

We evaluated the potential usefulness of 125I-labeled p-hydroxybupropion in a direct radioimmunoassay for bupropion in human plasma as compared with a currently used [3H]bupropion dextran-coated charcoal method. In both radioimmunoassay methods succinoylpropylbupropion antiserum was used that was highly specific for unchanged drug, cross reactivities with known bupropion metabolites being less ...

Journal: :Endocrinologia japonica 1974
H Sekihara T Yamaji N Osawa H Ibayashi

Dehydroepiandrosterone (DHEA) and its sulfate ester, dehydroepiandrosterone sulfate (DHEAS) are the major adrenal C19 steroids in man. Concerning DHEAS many extensive studies have been reported using Zimmerman reaction and gas-liquid chromatography. Only a few papers, however, have appeared concerning DHEA. One of the causes of minute amount of information about DHEA was the complicated assay p...

Journal: :Journal of clinical microbiology 1975
W D Leers G M Kouroupis

Radioimmunoassay for the detection of hepatitis B antigen has been accepted in many diagnostic laboratories now. The question of nonspecific positives has always been a matter of controversy. Two improved radioimmunoassay tests, namely Ausria II-125 by Abbott Laboratories and a radioimmunoassay method by Connaught Laboratories Limited (Hebria), were compared with the original Ausria 125I. Inclu...

Journal: :Clinical chemistry 1975
A R Berman J P McGrath R C Permisohn J A Cella

A commercial radioimmunoassay kit was evaluated for efficacy in detecting methaqualone or its metabolites in urine of persons receiving this drug. The drug and its unconjugated 3'- and 4'-monohydroxy metabolites could be detected equally well. The unconjugated alpha-monohydroxy metabolite was about 80% as reactive and the unconjugated 6-monohydroxy metabolite reacted only very weakly. Quantitat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید