نتایج جستجو برای: pvc based membrane
تعداد نتایج: 3283838 فیلتر نتایج به سال:
Blend reverse osmosis membranes were fabricated using polyvinyl chloride (PVC) with cellulose acetate (CA) as polymer blends. Tetrahydrofuran (THF) and N-Methyl-2-pyrrolidone (NMP) were used as solvents. The membrane polymer solution was cast on a coated woven fabric support material. The prepared membranes have been characterized by SEM and mechanical properties. SEM r...
PVC-441 murine leukemia virus (MuLV) is a member of the PVC group of Friend MuLV (F-MuLV)-derived neuropathogenic retroviruses. In order to determine the molecular basis for the difference in neuropathogenicity between PVC-441 and the previously characterized PVC-211 MuLVs, the entire nucleotide sequence of PVC-441 MuLV was determined and compared with those of PVC-211 and F-MuLV. The results s...
For the miniaturization of ISFET sensing systems, the concept of a REFET with low ion sensitivity is proposed to replace the conventional reference electrodes through the arrangement of a quasi reference electrode and a differential readout circuit. In this study, an ion-unblocking membrane was used as the top layer of a REFET. To optimize the REFET performance, the influences of the silylating...
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
Submit Manuscript | http://medcraveonline.com PVC has significant defects due to its quick decomposition at temperature higher than 130°C [3-5]. This process results in a significant change in color, reducing the mechanical properties and the generated HCl exacerbates the decomposition of PVC, so the usage of PVC thermal stabilizers is inevitable [4,6]. Our group had synthesized pentaerythritol...
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a goo...
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
A barbiturate receptor has proven effective in improving selectivity in solid-phase microextraction of barbiturates when doped into plasticized poly(vinyl chloride) (PVC). It would be beneficial to have selective extractions for any given organic species; however, the receptors do not exist. They will be found by screening of libraries of potential receptors; thus, a screening method is needed....
Exploratory (i.e., voxelwise) spatial methods are commonly used in neuroimaging to identify areas that show an effect when a region-of-interest (ROI) analysis cannot be performed because no strong a priori anatomical hypothesis exists. However, noise at a single voxel is much higher than noise in a ROI making noise management critical to successful exploratory analysis. This work explores how p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید