نتایج جستجو برای: neutron detector
تعداد نتایج: 103020 فیلتر نتایج به سال:
Many neutron-detection techniques are under consideration as potential replacements for 3 He gas-filled proportional tubes, which are widely used in international nuclear safeguards applications. The traditional 10 B-lined proportional tube is a commercial off-the-shelf (COTS) technology for neutron detection that predates the development of 3 He detectors. There is also a long history of its u...
Boron Neutron Capture Synovectomy (BNCS) is a novel application of the B(n,α) reaction for potential treatment of rheumatoid arthritis. During BNCS clinical trials, real-time knowledge of boron dose delivered to the synovium is necessary so that the remaining irradiation time can be determined. A 478 keV photon is emitted following 94% of boron neutron capture reactions, and detection of 478 ke...
.................................................................................................................................. iii ACKNOWLEDGEMENTS ............................................................................................................ v TABLE OF CONTENTS ............................................................................................................... vi L...
GEANT4 is a toolkit for simulating the passage of particles though matter, which contains a complete range of functionality including tracking, geometry, physics models, and hits. In this article, an attempt to use GEANT4 Monte Carlo code to watch a double-gap Resistive Plate Chamber's (RPC) response to neutrons is presented. The simulation calculations of the double-gap RPC have been evaluated...
چکیده ندارد.
A new approach to fast-neutron dosimeq is described. It involves circulating a liquid with dissolved chemicals between a localized neutron field and a remote area where neutron-induced radioactivities are measured continuously. This approach employs reactions whch generate relatively short-lived radioactive byproducts. Sensitivity to the neutron energy spectrum is achieved by choosing several r...
A novel technique for β-delayed neutron spectroscopy has been demonstrated using trapped ions. The neutron-energy spectrum is reconstructed by measuring the time of flight of the nuclear recoil following neutron emission, thereby avoiding all the challenges associated with neutron detection, such as backgrounds from scattered neutrons and γ rays and complicated detector-response functions. (137...
We discuss the possibility that future gravitational-wave detectors may be able to detect various modes of oscillation of old, cold neutron stars. We argue that such detections would provide unique insights into the superfluid nature of neutron-star cores, and could also lead to a much improved understanding of pulsar glitches. Our estimates are based on a detector configuration with several na...
The recoil proton energy response has been measured by exposing cylindrical cells, filled with BC501A BICRON liquid scintillator, to mono-energetic neutron reference fields. We determine the required calibration parameters and report the detailed procedures for the experimental data handling. A dedicated Montecarlo simulation has successfully been used to check the consistency of the experiment...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید