نتایج جستجو برای: net analyte signal

تعداد نتایج: 520623  

2017
Marcin S. Filipiak Marcel Rother Nesha M. Andoy Arne C. Knudsen Stefan B. Grimm Christopher Bachran Jana Zaumseil Alexey Tarasov

Nanomaterial-based field-effect transistors (FETs) have been proposed for real-time, label-free detection of various biological species. However, screening of the analyte charge by electrolyte ions (Debye screening) has so far limited their use in physiological samples. Here, this challenge is overcome by combining FETs based on single-walled semiconducting carbon nanotube networks (SWCNTs) wit...

2008
M. Hoenig H. Baeten

This work compares efficiencies of pneumatic and ultrasonic nebulizers and discusses drawbacks observed in trace element analyses of environmental matrices using ICP-AES with ultrasonic nebulization. The interference observed is mainly due to variable calcium content in samples; in most cases the excessive plasma loading by Ca is responsible for signal suppression of analyte elements. Such matr...

2013
Nunzio Cennamo Davide Massarotti Ramona Galatus Laura Conte Luigi Zeni

In silica optical fiber Surface Plasmon Resonance (SPR)-based sensors, an increase in fiber core diameter produces a corresponding increase in the sensitivity and Signal to Noise Ratio (SNR). In Plastic Optical Fiber (POF) realized in PMMA there are different influences of design parameters on the performance, as both sensitivity and SNR are concerned. In particular, the SNR, for different refr...

1997
Se-Hwan Paek

In a competitive enzyme immunoassay, the performance was tested with different analyte-enzyme conjugates (signal generators) in their binding constants to antibody. Analyte (progesterone)-enzyme (glucose oxidase; GO) conjugates were chemically synthesized and purified by using a gel column with an immobilized antibody to progesterone. In an elution range from the column, four peaks were detecte...

2017
Hamid Reza Zafarani Klaus Mathwig Ernst J. R. Sudhölter Liza Rassaei

We report a strategy for the fabrication of a new type of electrochemical nanogap transducer. These nanogap devices are based on signal amplification by redox cycling. Using two steps of electron-beam lithography, vertical gold electrodes are fabricated side by side at a 70 nm distance encompassing a 20 attoliter open nanogap volume. We demonstrate a current amplification factor of 2.5 as well ...

Journal: :The Analyst 2011
Chad L Cowles Xiaoshan Zhu Nelson G Publicover

In this work, a fluorescence signal transduction mechanism based on cation release from ZnS nanocrystals was developed for sandwich immunoassay. In this mechanism, ZnS nanocrystals as labels in immunoassay are dissolved by acid to release zinc ions. After pH adjustment of the dissolving solution using a basic solution, zinc-ion sensitive fluorescence indicator Fluozin-3 is added to bind with th...

2018
Sophie Patze Uwe Huebner Karina Weber Dana Cialla-May Juergen Popp

Surface-enhanced Raman spectroscopy (SERS) is known as a molecular-specific and highly sensitive method. In order to enable the routine application of SERS, powerful SERS substrates are of great importance. Within this manuscript, a TopUp SERS substrate is introduced which is fabricated by a top-down process based on microstructuring as well as a bottom-up generation of silver nanostructures. T...

Journal: :IEEE Access 2021

Images taken in extremely low light suffer from various problems such as heavy noise, blur, and color distortion. Assuming the low-light images contain a good representation of scene content, current enhancement methods focus on finding suitable illumination adjustment but often fail to deal with noise Recently, some works try suppress reconstruct raw data. But these apply network instead an im...

Journal: :Remote Sensing 2022

Jamming will seriously affect the detection ability of radar, so it is essential to suppress jamming radar echoes. Interrupted-sampling repeater (ISRJ) based on a digital-radio-frequency-memory (DRFM) device can generate false targets at victim by interception and repeating transmission signal, which highly correlated with true target signal. ISRJ achieve main lobe has both deception oppressive...

Journal: :Analytical chemistry 2000
R D JiJi K S Booksh

A weighted parallel factor analysis (W-PARAFAC) model is applied to excitation-emission matrix (EEM) fluorescence spectra of carbamate pesticides to aid with calibration in the presence of Raman scattering. Traditional PARAFAC inefficiently models the Raman scattering, resulting in prediction and calibration errors when a significant background is present. Four different weighting strategies we...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید