نتایج جستجو برای: myocardial perfusion gated spect
تعداد نتایج: 230910 فیلتر نتایج به سال:
introduction: the aim of this study was to evaluate the impact of measurement of coronary artery calcification score (cac) in patients with suspected coronary artery disease (cad) and a normal myocardial perfusion scan. methods: in a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of cad and a normal perfusion scan. in ...
BACKGROUND Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion...
introduction: motion of the patient during myocardial perfusion spect could potentially results in false perfusion defects. the effect of different reconstruction methods on these artifacts is not studied. clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. this study...
introduction: the main purpose of this study was to compare transient ischemic dilation (tid) ratios in spect-low dose ct and spect myocardial perfusion imaging (mpi) by application of different quantitative programs and quantify the possible shift in the upper normal limits of tid ratio in the spect-ct mpi. methods: 149 patients with low pre-test probability for coronary artery disease (cad),...
Abstract Purpose of Review The purpose this review is to provide a summary on the status art simultaneous perfusion-innervation imaging by CZT-SPECT and clarify its potential applications in clinical practice. Recent Findings Introduction CZT cameras represented critical breakthrough nuclear cardiology. Although it has been demonstrated that cardiac innervation may be easily assessed CZT-SPECT,...
Abstract Funding Acknowledgements Type of funding sources: None. Aim/Introduction: Assessment mechanical dyssynchrony by myocardial perfusion gated-SPECT in patients with non-ischemic cardiomyopathy for predict response to cardiac resynchronization therapy (CRT). Materials and Methods We examined 32 before six months after CRT. Left ventricular contractility were assessed all gated-SPECT. The p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید