نتایج جستجو برای: mcnp design
تعداد نتایج: 960935 فیلتر نتایج به سال:
A brief survey of plastic scintillators for various radiation measurement applications is presented here. The utility of plastic scintillators for practical applications such as gamma radiation monitoring, real-time radioisotope detection and screening is evaluated in laboratory and field measurements. This study also reports results of Monte Carlo-type predictive responses of common plastic sc...
Standard neutron fields are invariably accompanied by a photon component due to the neutron-generating reactions and secondary neutron interactions in the surrounding environment. A set of energy-compensated Geiger-Müller (GM) tubes and electronic personal dosemeters (EPDs) have been used to measure the photon dose rates in a number of standard radionuclide and accelerator-based neutron fields....
در این تحقیق، چشمه بتازای 90Sr/90Y مورد بررسی قرار گرفته است که چگونه میتوان با استفاده از میدان مغناطیسی حاصل از یک حلقه حامل جریان، آن را تکفام نمود. سپس با توجه به انحراف الکترون در میدان مغناطیسی، طیف انرژی خروجی از پنجره خروجی حلقه حامل جریان، با استفاده از کد شبیهساز مونتکارلو MCNP به دست آمده است. در این تحقیق، چشمه بتازای 90Sr/90Y مورد بررسی قرار گرفته است که چگونه میتوان با استفاده...
یکی از بهترین روشها برای مدیریت ضایعات زغالسنگ در راستای جلوگیری از انباشت آنها در طبیعت و کاهش آلودگیهای محیطزیست، کاربرد آنها بهعنوان جاذب آلایندهها است. این پژوهش با هدف بررسی قابلیت و رفتار جذبی ضایعات زغالسنگ به سه شکل پودری خام (cp)، نانو ذرات (cnp) و نانو ذرات اصلاحشده با کلرید آهن (mcnp) در جذب فسفر از محلول آبی انجام شد. مشخصهیابی جاذبها با استفاده از آنالیزهای دستگاهی نظی...
For the first time, measurements of the time-dependent cross-correlation distributions of plutonium oxide have been made separately for neutrons and gamma rays. Six EJ-309 liquid scintillation detectors with a digital, offline pulse shape discrimination and pulse timing method were used to measure five different samples of varying mass and burnup. The number of (neutron, neutron) correlations w...
Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measu...
The European Directive 96/29/EURATOM and adapted national regulations on radiation protection are claiming new limits of radiation exposure and the introduction of new measuring quantities. Dosimeters for area monitoring of penetrating X-ray and gamma radiation have to measure the ICRU operational quantity ambient dose equivalent, H*(10). In this paper, the development stages of a passive H*(10...
It is of interest to discern the energy-dependence of American Association of Physicists in Medicine (AAPM) TG-43 brachytherapy dosimetry parameters. Using Monte Carlo calculation geometry and techniques (MCNP), dependence of these parameters was calculated as a function of photon energy, in general, and for the MED3633 103Pd source using a discretized approach. Results were weighted and summed...
NCRP 151 provides very detailed examples demonstrating the necessary concerns for shielding a conventional radiotherapy vault with a maze where the useful beam is parallel to the maze. However, it provides little guidance on how to properly shield a vault with the maze-wall acting as part of a compound primary barrier. We have modeled a new radiotherapy vault with this configuration and assesse...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید