نتایج جستجو برای: intercrystal scatter

تعداد نتایج: 12386  

Journal: :Physics in medicine and biology 2008
Sarah E Bohndiek Emily J Cook Costas D Arvanitis Alessandro Olivo Gary J Royle Andy T Clark Mark L Prydderch Renato Turchetta Robert D Speller

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate i...

2011
Rostislav Khlebnikov Bernhard Kainz Bernhard Roth Judith Muehl Dieter Schmalstieg

We present a novel on-the-fly scatter approximation scheme that can be applied concurrently to multiple volumetric datasets. We use a simplified version of the emission-absorption model, including single scattering and shadowing and guide the scatter sample positions and in-scatter coefficients by local gradients. This allows us to render multiple intersecting volumes with our rendering system ...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2001
Z Lee M Ljungberg R F Muzic M S Berridge

UNLABELLED Planar gamma-scintigraphy is often used to quantify pulmonary deposition patterns from aerosol inhalers. The results are quite different from those obtained using 3-dimensional PET and SPECT. The purpose of this study was to characterize the effects of scatter and tissue attenuation on the distribution of radiolabeled aerosol as measured by planar scintigraphy using Monte Carlo simul...

Journal: :Physics in medicine and biology 2000
I Laurette G L Zeng A Welch P E Christian G T Gullberg

The qualitative and quantitative accuracy of SPECT images is degraded by physical factors of attenuation, Compton scatter and spatially varying collimator geometric response. This paper presents a 3D ray-tracing technique for modelling attenuation, scatter and geometric response for SPECT imaging in an inhomogeneous attenuating medium. The model is incorporated into a three-dimensional projecto...

2004
Yong Liu

From the process of scatter-gather algorithm explained above, we can easily find the essence of the parallel version of this algorithm is the parallel clustering algorithm used in the scatter phase. Frieder, et al. implements a parallel version of the buckshot clustering algorithm [1]. Their work meets the need of the parallel scatter-gather clustering algorithm pretty well, although we can des...

Journal: :Applied optics 2013
David J Brady Daniel L Marks Kenneth P MacCabe Joseph A O'Sullivan

We examine coding strategies for coded aperture scatter imagers. Scatter imaging enables tomography of compact regions from snapshot measurements. We present coded aperture designs for pencil and fan beam geometries, and compare their singular value spectra with that of the Radon transform and selected volume tomography. We show that under dose constraints scatter imaging improves conditioning ...

2005
I. M. Rodrigues G. Boente A. M. Pires

In multivariate analysis we often deal with situations involving several populations, such as discriminant analysis, where the assumption of equality of scatter matrices is usually assumed. Yet sometimes, this assumption is not adequate but problems related to an excessive number of parameters will arise if we estimate the scatter matrices separately for each population. In many practical situa...

2016
Masanobu Ibaraki Keisuke Matsubara Kaoru Sato Tetsuro Mizuta Toshibumi Kinoshita

OBJECTIVE Positron emission tomography (PET) enables quantitative measurements of various biological functions. Accuracy in data acquisition and processing schemes is a prerequisite for this. The correction of scatter is especially important when a 3D PET scanner is used. The aim of this study was to validate the use of a simplified calculation-based scatter correction method for 15O studies in...

2000
Victor Venema Jan Erkelens Herman Russchenberg Leo Ligthart

Well-known radar scattering mechanisms are Rayleigh scattering (incoherent particle scattering), and clear-air scattering (coherent air scattering). This article discusses the importance in clouds of these two mechanisms compared to a third scattering mechanism: coherent particle scattering, which is caused by spatial variations in the liquid water content of the clouds. We will argue that for ...

2001
Zhenghong Lee Michael Ljungberg Raymond F. Muzic Marc S. Berridge

Planar g-scintigraphy is often used to quantify pulmonary deposition patterns from aerosol inhalers. The results are quite different from those obtained using 3-dimensional PET and SPECT. The purpose of this study was to characterize the effects of scatter and tissue attenuation on the distribution of radiolabeled aerosol as measured by planar scintigraphy using Monte Carlo simulations. This st...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید