نتایج جستجو برای: goldmann applanation tonometer

تعداد نتایج: 2316  

Journal: :Investigative ophthalmology & visual science 2009
Francis Carbonaro Toby Andrew David A Mackey Terri L Young Tim D Spector Christopher J Hammond

PURPOSE To analyze the effect of using one reading, the mean of two readings (from the same eye), or the mean of four readings (two from each eye) on the heritability estimates of intraocular pressure (IOP). This was a cohort study in which 344 pairs of twins, 163 monozygotic (MZ) and 181 dizygotic (DZ), were enrolled. METHODS IOP was measured using three tonometers: the gold standard Goldman...

Journal: :Investigative ophthalmology & visual science 1997
B Entenmann Y C Robert P Pirani H Kanngiesser P W Dekker

PURPOSE To establish a standard clinical procedure for measuring intraocular pressure (Po) with the contact lens tonometer (CLT), to demonstrate possibilities for analyzing ocular pulsation and performing ophthalmodynamometry. METHODS A reliable histogram-based analyzing system for determining Po is used. First, the ocular pressure was registered with the CLT method and compared with the Gold...

2002
Peter Marchetto Tara Alvarez Richard Greene Gordon Thomas

Most patients with glaucoma exhibit elevated intraocular pressure (IOP). A cost effective device that allows the patient to measure IOP at regular intervals may reduce vision loss. This research tested the Bausch & Lomb Proview self tonometer against a calibrated force meter. It further compared the Proview tonometer with results from the clinical gold standard, the Goldmann tonometer. Results ...

2014
Lei Tian Yi-Fei Huang Li-Qiang Wang Hua Bai Qun Wang Jing-Jing Jiang Ying Wu Min Gao

Purpose. To compare the corneal biomechanical properties of keratoconic patients and age-matched controls using corneal visualization Scheimpflug technology (Corvis ST). Methods. Sixty keratoconic eyes from 47 keratoconus patients and 60 normal eyes from 60 controls were enrolled in this prospective study. Tomography and biomechanical parameters of all eyes were obtained with the Pentacam and C...

2011
Silvia Franco Andrade Daniel Silva Kupper Luiz Fernando Rodrigues de Pinho Elizabeth Cunha Franco Marcus Vinícius Felix Fabri Prataviera Rodrigo Rolim Duarte José Ricardo Cecílio Junqueira

The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anes...

Journal: :The British journal of ophthalmology 2005
P-A Tonnu T Ho T Newson A El Sheikh K Sharma E White C Bunce D Garway-Heath

AIMS To evaluate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements made with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT). METHODS CCT was recorded for either eye (randomly selected) of each of 105 untreated patients with ocular hypertension and glaucoma attending...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید