نتایج جستجو برای: glaucoma drainage implant
تعداد نتایج: 112612 فیلتر نتایج به سال:
Neovascular glaucoma is a challenging disease in its pathogenesis and treatment. Ischemic retinopathies can lead to neovascular glaucoma due to newly formed vessels on the iris surface and anterior chamber angle. Eyes with neovascular glaucoma can exhibit high intraocular pressure, usually treated by retinal coagulation, cyclodestructive procedures, or drainage procedures. Based on experimental...
glaucoma is the leading cause of preventable blindness worldwide. despite tremendous advances in medical and surgical management of glaucoma in the recent years, the prevalence of glaucoma related blindness is anticipated to increase in the future decades because of the aging population. stem cells have the potential to change the glaucoma management in several ways. there are several areas of ...
Purpose: This case report illustrates the difficult management of complications produced following the bilateral iris implant of the NewColorIris (NewColorIris, Kahn, and Medical Devices. Methods: We report the case of a 36-year-old man who was referred to our outpatient clinic because of bilateral glaucoma showing a poor response to medical treatment and anti-glaucoma surgery. The young man ha...
A variety of inherited animal models with different genetic causes and distinct genetic backgrounds are needed to help dissect the complex genetic etiology of glaucoma. The scarcity of such animal models has hampered progress in glaucoma research. Here, we introduce a new inherited glaucoma model: the inbred mouse strain YBR/EiJ (YBR). YBR mice develop a form of pigmentary glaucoma. They exhibi...
BACKGROUND Proton beam therapy (PBT) is effective in the treatment of iris melanoma. Reported complications after PBT are radiation-induced cataract and raised intraocular pressure (IOP). Filtering glaucoma surgery has generally been avoided because of fears of seeding. CASE REPORT A 37-year-old man presented with a self-discovered, pigmented lesion on his right iris. Four years later, the pi...
AIM To investigate the rate, risk factors, clinical course, and treatment outcomes of endophthalmitis following glaucoma drainage implant (GDI) surgery. METHODS A computerised relational database search was conducted to identify all patients who were implanted with Ahmed glaucoma valve (AGV) and developed endophthalmitis following surgery at the King Khaled Eye Specialist Hospital in Riyadh, ...
AIMS To evaluate the clinical efficacy of membrane tube implant made of expanded polytetrafluoroethylene (e-PTFE, Gore-Tex) membrane and silicone tube in treating refractory glaucoma. METHODS A retrospective chart review was performed on 43 eyes of 40 patients who underwent glaucoma tube shunt implant surgery using double layered e-PTFE membrane and silicone tube to treat refractory glaucoma....
We present our experience with implantation of an Ahmed glaucoma valve in a 9-year-old girl with Sturge-Weber syndrome with choroidal hemangioma. In this case of childhood glaucoma, the choice of surgical procedure should be based on the efficacy and elimination of intra-and post-operative complications. An Ahmed glaucoma valve offered safety and efficacy in controlling glaucoma. This technique...
AIM To describe the surgical management of glaucoma in a patient with severe scleromalacia, and secondary angle closure. INTRODUCTION The management of glaucoma with coexisting scleromalacia plus secondary angle closure is challenging as most commonly performed incisional glaucoma surgery as well as minimally invasive glaucoma surgery (MIGS), which targets the drainage angle are all contraind...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید