نتایج جستجو برای: gas cooling tower
تعداد نتایج: 303152 فیلتر نتایج به سال:
Flow cytometry, using fluorescein-bound specific antibodies and propidium iodide, was shown to be effective in detecting Legionella spp. in cooling tower waters. The procedure was quicker and less labor intensive than fluorescent microscopy. The use of these procedures also identified qualitative differences, perhaps related to infectivity, in Legionella populations.
The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept a...
1 Abstract The existence of cooling flows in the center of galaxy clusters has always been a puzzle, and in particular the fate of the cooling gas, since the presence of cold gas has never been proven directly. X-ray data from the satellites Chandra and XMM-Newton have constrained the amount of cooling, and it was realized that feedback and heating from a central AGN and its jets could reduce t...
We report here the complete genome sequences of two of the earliest known strains of Legionella pneumophila subsp. fraseri Detroit-1 is serogroup 1 and was isolated from a lung biopsy specimen in 1977. Dallas 1E is serogroup 5 and was isolated in 1978 from a cooling tower.
A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...
Theoretical investigation of combining cooling tower and cooling coil with direct evaporative cooler
Abstract A theoretical study is developed to examine the feasibility of using cooling tower and coil with direct evaporative cooler in highest summer temperature Karbala/Iraq. This due inability reducing outside air efficiency reduction mechanical vapor compression systems despite its high electrical energy consumption at temperatures. The water cooled a higher than outdoor wet-bulb by (3.9 $$^...
Nuclear and other large-scale energy-producing plants must include systems that guarantee the safe discharge of residual heat from the industrial process into the atmosphere. This function is usually performed by one or several cooling towers. The amount of heat released by a cooling tower into the external environment can be quantified by using a numerical simulation model of the physical proc...
We use a one-dimensional hydrodynamical code to investigate the effects of preheating on gas accretion and cooling in cold dark matter halos. In the absence of radiative cooling, preheating reduces the amount of gas that can be accreted into a halo, and the accreted gas fraction is determined by the ratio of the initial specific entropy of the gas to the virial entropy of the halo, Sph/Sv. In t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید