نتایج جستجو برای: gafchromic ebt2

تعداد نتایج: 444  

Journal: :Journal of Applied Clinical Medical Physics 2015

Journal: :Medical physics 1999
J Y Cheung K N Yu R T Ho C P Yu

The Monte Carlo technique and GafChromic films were employed to verify the accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (type B) radiosurgery when plugged collimator helmets were used. The EGS4 Monte Carlo code was used to calculate the dose distribution along the x, y, and z axes when a single shot was delivered at the center point (unit center point: x = 100, y...

2011
Mario de Denaro Paola Bregant

BACKGROUND The technologic improvements in Multislice scanners include the increment in the X-ray beam width. Some new CT scanners are equipped with a 320 detector row which allows a longitudinal coverage of 160 mm and a total of 640 slices for a single rotation. When such parameters are used the length of the traditional pencil chamber (10 cm) is no more appropriate to measure the standard wei...

2012
Mahdi Ghorbani Mohammad Taghi Bahreyni Toossi Ali Asghar Mowlavi Shahram Bayani Roodi Ali Soleimani Meigooni

UNLABELLED BACKGROUND.: The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. MATERIALS AND METHODS A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 (60)Co brachytherapy source with GafChromic® EBT...

2011
Paola Pinnarò Antonella Soriani Daniela D'Alessio Carolina Giordano Maria Laura Foddai Valentina Pinzi Lidia Strigari

OBJECTIVES To implement a new cost efficacy internal Service for blood component irradiation, we carried out specific procedures and quality assurance reports using the linear accelerators (LINACs) of the Regina Elena Institute (IRE) Radiotherapy Department instead of a dedicated device. METHODS The technical aspects, quality assurance and regulatory requirements of the internal procedure to ...

Journal: :Physics in medicine and biology 2004
Martin J Butson Tsang Cheung Peter K N Yu

The visible absorption spectra of Gafchromic XR type-T radiochromic film have been investigated to analyse the dosimetry characteristics of the film with visible light densitometers. Common densitometers can use photospectrometry, fluorescent light (broad-band visible), helium neon (632 nm), light emitting diode (LED) or other specific bandwidth spectra. The visible absorption spectra of this f...

Journal: :Medical physics 2013
M Carroll G Ibbott M Gillin J Adamovics

PURPOSE This investigation studies the feasibility of PRESAGE, a 3D polyurethane dosimeter, for relative dosimetry measurements of clinically relevant proton treatments using an anthropomorphic head phantom developed by the Radiological Physics Center (RPC). Performance of a low-LET dependent PRESAGE was evaluated by comparison to the traditionally used radiochromic film, EBT2, and thermolumine...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید