نتایج جستجو برای: flow injection analysis
تعداد نتایج: 3320469 فیلتر نتایج به سال:
A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with potassium permanganate in a nitric acid medium. A strong chemiluminescence signal was observed when ferulic acid was injected into an acidic potassium permanganate solution in a flow-cell. The present method a...
Present needs have forced the growth and improvement of analytical methods; an area of analytical chemistry which has received a great deal of attention over the last few decades is automatic analysis, with many and varied instruments having been developed and commercialized.
An overview of the use of immobilized enzymes in flow-injection analysis (FIA) is presented. The joint use of FIA and immobilized enzymes means that analytical procedures are easily automated, analytical costs are reduced and methods are faster. The future possibilities for this combination are discussed.
The development of a competitive solid-phase immunoassay for digoxin making use of the acridinium chemiluminescence system is described. Two different instrumental approaches are compared. One is based on a continuous flow system using a peristaltic flow injection analysis pump; the other uses a new sequential injection technique. In both systems a flow cell, consisting of transparent PTFE tubi...
Noscapine is an antitussive drug and possesses potent antitumor activity. This work establishes a highly sensitive method for its determination by flow injection chemiluminescence (CL) technique. This method is based on its strong sensitizing effect on the weak CL reaction between sulfite and acidic permanganate. The mechanism for the sensitizing process is proposed on the basis of fluorescence...
A flow injection configuration (FIA) based on a galvanic detector for the determination of nitrogen dioxide is described. The gaseous sample is directly injected into a gaseous carrier. The sample is transported toward the detector. The steady state measurements are not required to obtain the reproducible peak signals. The features of FIA are compared with that of continuous flow monitoring app...
Cells of Zymomonas mobilis possessing glucose-fructose oxidoreductase and gluconolactonase were permeabilized with toluene and co-immobilized with invertase within a gelatin membrane. This membrane was coated over a pH electrode, and the resulting biosensor was placed in a flow-through cell to develop a flow injection analysis (FIA) system for the specific determination of glucose, fructose, an...
A theoretical model for carbon dioxide (CO2) migration in tilted aquifers with groundwater flow is presented to evaluate the injection of CO2 into a geological formation. Capillary force in the flow of two immiscible fluids in a porous medium creates a saturation transition zone, where the saturation changes gradually. A vertical equilibrium assumption is employed to solve for the capillary pre...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید