نتایج جستجو برای: flat panel detector x ray

تعداد نتایج: 844034  

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2009
Tokitaka Ueno Ryuji Nakamuta Tadahisa Uemura Kunihiro Matsumoto Toshihiro Maeda Shigeki Ono Yoshihiro Kozawa Shogo Kojima

Optical density of the lung area in pediatric digital chest radiography using an indirect flat panel detector (FPD) system were changed enormously by the influence of such factors as the size of lung area, gas of retroperitoneum, and so on. Our purpose in this study was to improve the stability of lung density on output images by means of optimizing histogram analysis. Chest images of a lung ph...

Journal: :AJNR. American journal of neuroradiology 2011
D L Cooke M Levitt L J Kim D K Hallam B Ghodke

FPCT and navigation software on contemporary fluoroscopic units perform imaging of a quality comparable with conventional CT. They can accurately guide percutaneous procedures, providing live instrument visualization and the capability to re-image without patient transfer. FPCT navigation was used in the placement of a ventricular drain in a 62-year-old woman for subarachnoid-related hydrocepha...

Journal: :IEEE Access 2022

For fluoroscopic imaging, flat-panel dynamic detectors can acquire X-ray image sequences with frame rates higher than 300 frames per second. However, the sequentially acquired images have artifacts due to lag signals, which are caused from trapping charges in amorphous structure and incomplete reads. Furthermore, signal lowers noise power spectrum (NPS) of detector; hence, detector performance ...

2002
Wayne H. Baumgartner K. Tamura

The CZT detector on the InFOCμS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20–40 keV. The detector has an energy resolution of 4.0 keV at 32 k...

2015
CAN OZCAN

The aim of this paper is to empirically investigate the determinants of tourism demand by utilizing panel data for the period of 1995-2011 from top 20 countries sending tourists to Turkey. Econometric results obtained from panel cointegration analysis show that macroeconomic factors as such income, prices, supply capacity, exchange rate and political stability play a significant role in determi...

Journal: :IEEE Transactions on Nuclear Science 2001

Journal: :Journal of synchrotron radiation 2009
T Ejdrup H T Lemke K Haldrup T N Nielsen D A Arms D A Walko A Miceli E C Landahl E M Dufresne M M Nielsen

The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 ...

Journal: :IEEE Transactions on Nuclear Science 2002

2005
M. Hoheisel R. Lawaczeck H. Pietsch V. Arkadiev

The contrast of X-ray imaging depends on the radiation energy and acquires its maximum value at a certain optimum energy typical for the object under investigation. Usually, higher energies result in reduced contrast, lower energies are absorbed in the object thus having a smaller probability of reaching the detector. Therefore, broad X-ray spectra contain non-optimal quanta to a large extent a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید