نتایج جستجو برای: film dosimeter

تعداد نتایج: 92845  

Arass Rasaei, Raheleh Rooshenas

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

Journal: :Journal of the Ceramic Society of Japan 2013

Journal: :Brazilian Journal of Radiation Sciences 2023

Radiation dosimetry has the purpose of quantifying dose received by occupationally exposed individual. The device used in this process is called a dosimeter, dosimeter can be different situations, for example, to quantify fingers ring model extremity, which focus work. In Brazil, we still do not have standards calibration extremity dosimeters, therefore, work, CASEC recommendations were used, a...

Journal: :journal of biomedical physics and engineering 0
s. m. j. mortazavi professor of medical physics, department of medical physics and medical engineering, school of medicine, shiraz university of medical sciences, shiraz, iran n. omidifar pathology resident, pathology department, school of medicine, shiraz university of medical sciences, shiraz, iran r. faghihi nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran s. mehdizadeh nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran s. masoumi the center for radiological research, shiraz university of medical sciences, shiraz, iran s. m. hashemi the center for radiological research, shiraz university of medical sciences, shiraz, iran

background: the number of interventional cardiology procedures performed has increased rapidly over the past years. while these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. the dose received by the cardiologist during interventional cardiology procedures is determi...

F. Nowrouz-Alizadeh M. Haghani M. M. Movahhedi N. Omidifar R. Faghihi S. M. Hashemi S. M. J. Mortazavi S. Masoumi S. Mehdizadeh

Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...

Journal: :Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology 2012
Donald W Cockcroft Beth E Davis

Whenmethacholine is inhaledwith total lung capacity inhalations, which is the recommended inhalation pattern for the 5-breath dosimeter method,1 as many as a quarter of asthmatic patients can have a false-negative test result.2 It has been suggested to us that high forced expiratory volume in 1 second (FEV1) could explain negative (dosimeter) methacholine test results in patients with asthma. W...

Journal: :iranian journal of radiation research 0
k.l. sriharsha 1department of studies in environmental science, university of mysore, manasagangotri, mysore –570 006,karnataka, india m. raghavayya 1department of studies in environmental science, university of mysore, manasagangotri, mysore –570 006,karnataka, india n.r. rajendra prasad 2department of environmental science, st. philomena’s college, mysore –570 015, karnataka, india m.s. chandrahekara 3department of studies in physics, university of mysore, manasagangotri, mysore –570 006, karnataka, india

background: humans beings are continuously exposed to ionizing radiation from natural sources. the main contributors to natural radiation are high-energy cosmic radiation and radioactive nuclides that originates in the earth’s crust. exposure to high levels of radiation can cause serious health effects. in this study an attempt has been made to monitor the levels of environmental background rad...

2013
T Gorjiara C Baldock

Micelle gel is a radiochromic hydrogel with the potential to be used as a three dimensional (3D) radiation dosimeter. Since an ideal dosimeter should present water equivalent properties, in this study the water equivalence of two formulations of micelle gel has been investigated by calculating electron density, effective atomic number, fractional interaction probabilities, mass attenuation coef...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید