نتایج جستجو برای: field scanner

تعداد نتایج: 803839  

2009
S. Surti

A new detector design using pixelated NaI(Tl) crystals has been evaluated for use in positron emission tomography (PET). This detector uses 4 4 30 mm NaI(Tl) pixels coupled via a lightguide (1.4 cm thick) to an array of 39 mm diameter photomultiplier tubes (PMTs) in an Anger detector design. Our measurements show that the high light output of NaI(Tl) leads to a good discrimination of the 4 mm N...

Hojatollah Shahbazian Jafar Fatahiasl Mansour Zabihzadeh Mohammad Ali Behrooz Mohammad Javad Tahmasebibirgani Nahid Chegeni Reza Maskani

Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the d...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2016
Ottavia Bertolli Afroditi Eleftheriou Matteo Cecchetti Niccolò Camarlinghi Nicola Belcari Charalampos Tsoumpas

Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image r...

2008
R. Krug P. E. Larson C. Wang A. J. Burghardt D. A. Kelley T. M. Link X. Zhang D. Vigneron S. Majumdar

Introduction MRI at ultra-high field (UHF) strength of 7 Tesla has been increasingly used and optimized for in vivo applications over the past few years. In particular, the increased signal to noise ratio (SNR) renders this new modality very attractive for imaging soft tissues in the human body. More solid or semi-solid tissues such as trabecular and cortical bone provide little to no signal in...

2008
A. TANÁCS Z. KISS A. NAGY B. SCHILLINGER

In November of 2005 a measurement series was conducted on different kinds of reference objects to compare the results of the FRM-II (ANTARES) and the Budapest (Radiography Station) research reactor in the field of neutron radiography, gamma radiography, classical tomography and discrete tomography by an ANDOR CCD camera and Imaging plate with BAS 2500 Scanner (contributed by AIDA software).

Journal: :Advanced materials 2016
Alexey P Slobozhanyuk Alexander N Poddubny Alexander J E Raaijmakers Cornelis A T van den Berg Alexander V Kozachenko Irina A Dubrovina Irina V Melchakova Yuri S Kivshar Pavel A Belov

It is revealed that the unique properties of ultrathin metasurface resonators can improve magnetic resonance imaging dramatically. A metasurface formed when an array of metallic wires is placed inside a scanner under the studied object and a substantial enhancement of the radio-frequency magnetic field is achieved by means of subwavelength manipulation with the metasurface, also allowing improv...

Journal: :Chemical communications 2015
Zheng Li Will P Bassett Jon R Askim Kenneth S Suslick

Forensic identification of batches of homemade explosives (HME) poses a difficult analytical challenge. Differentiation among peroxide explosives is reported herein using a colorimetric sensor array and handheld scanner with a field-appropriate sampling protocol. Clear discrimination was demonstrated among twelve peroxide samples prepared from different reagents, with a classification accuracy ...

2013
GS Sim JHD Wong KH Ng

Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek S...

2017
S. Lew M.S. Hämäläinen Y. Okada

OBJECTIVE To evaluate whether a full-coverage fetal-maternal scanner can noninvasively monitor ongoing electrophysiological activity of maternal and fetal organs. METHODS A simulation study was carried out for a scanner with an array of magnetic field sensors placed all around the torso from the chest to the hip within a horizontal magnetic shielding enclosure. The magnetic fields from intern...

Journal: :International Journal For Multidisciplinary Research 2023

This study focused on analysing the effectiveness of some CT scanner models; in this concern, selected Siemens Medical Scanner, Philip and GE Discovery STE. gathered primary data, which was scan report a patient, used by Scanner. presented patient’s scanning for five years, allowed comparative among these three machines. found that Scanner is less reliable due to its noise-reduction technique, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید