BACKGROUND AND PURPOSE CVJ lesion suffers from a high sensitivity to susceptibility and distortion artifacts, which sometimes makes diffusion image difficult to interpret. Our purpose was to evaluate the potential for diffusion MR imaging using RS-EPI compared with SS-EPI in the assessment of the CVJ. MATERIALS AND METHODS RS-EPI and SS-EPI DTI images were acquired from 10 healthy volunteers ...
BACKGROUND AND PURPOSE Previous reports have shown that DWI is useful in detecting cholesteatoma. SS-EPI is the most widely used DWI technique. However, SS-EPI may have susceptibility artifacts due to field inhomogeneity in the imaging of the temporal bone region. Our purpose was to prospectively evaluate the advantage of MS-EPI for the diagnosis of middle ear cholesteatoma by comparing it with...
There is growing evidence as to the benefits of collecting BOLD fMRI data with increased sampling rates. However, many of the newly developed acquisition techniques developed to collect BOLD data with ultra-short TRs require hardware, software, and non-standard analytic pipelines that may not be accessible to all researchers. We propose to incorporate the method of shifted echo into a standard ...
Introduction: Low frequency fluctuations (LFFs) in T2*-weighted MR images have been used to map functional connectivity in both humans and rats [1, 2, 3]. Most FC studies utilize gradient echo EPI (GE-EPI) because of its high sensitivity to BOLD signal fluctuations. However, fMRI studies have shown that the BOLD signal in GE-EPI images contains a strong contribution from large veins. At high fi...
Aspirin (ASA) triggers the formation of 15-epi-lipoxins (15-epi-LXs or ATL [ASA-triggered LX]), which are potent bioactive eicosanoids that may contribute to the therapeutic impact of ASA. To elucidate the role of these new compounds in vivo, it is essential to establish quick and sensitive detection methods. To this end, we prepared an enzyme-linked immunosorbent assay specific for 15-epi-LXA4...
Plasma or serum extrinsic pathway inhibitor (EPI) activity was measured in 24 patients with disseminated intravascular coagulation (DIC) and in 23 patients with severe hepatocellular disease. EPI was measured as activity in a test sample that inhibited factor VIIa/tissue factor (TF)-catalyzed activation of 3H-factor IX (activation peptide release) in the presence of factor X. Of the 24 patients...
Magnetic field inhomogeneity causes artifacts in MRI. For example, in single-shot echo-planar imaging (EPI), they often appear as severe geometric distortions along the phase-encoding direction. Sensitivity encoding (SENSE) is useful in reducing the distortion in EPI since it only acquires partial k-space data using multiple receiver channels. In SENSE, a reference scan usually needs to be perf...
PURPOSE To introduce a new k-space traversal strategy for segmented three-dimensional echo planar imaging (3D EPI) that encodes two partitions per radiofrequency excitation, effectively reducing the number excitations used to acquire a 3D EPI dataset by half. METHODS The strategy was evaluated in the context of functional MRI applications for: image quality compared with segmented 3D EPI, tem...