نتایج جستجو برای: electrochemical biosensor

تعداد نتایج: 59442  

Journal: :Analytica chimica acta 2011
Marta Kowalska Faming Tian Mária Šmehilová Petr Galuszka Ivo Frébort Richard Napier Nicholas Dale

An electrochemical biosensor for detection of the plant hormone cytokinin is introduced. Cytokinin homeostasis in tissues of many lower and higher plants is controlled largely by the activity of cytokinin dehydrogenase (CKX, EC 1.5.99.12) that catalyzes an irreversible cleavage of N(6)-side chain of cytokinins. Expression of Arabidopsis thaliana CKX2 from Pichia pastoris was used to prepare pur...

2011
Carlos Morón Enrique Tremps Alfonso Garcia Jose Andrés Somolinos Juan de Herrera

In this work, electrochemical maltose biosensors based on mutants of the maltose binding protein (MBP) are developed. A ruthenium complex (Ru), which is covalently attached to MBP, serves as an electrochemical reporter of MBP conformational changes. Biosensors were made through direct attachment of Ru complex modified MBP to gold electrode surfaces. The responses of some individual mutants were...

Journal: :ACS sensors 2017
Rupesh K Mishra Lee J Hubble Aida Martín Rajan Kumar Abbas Barfidokht Jayoung Kim Mustafa M Musameh Ilias L Kyratzis Joseph Wang

A flexible glove-based electrochemical biosensor with highly stretchable printed electrode system has been developed as a wearable point-of-use screening tool for defense and food security applications. This disposable-mechanically robust "lab-on-a-glove" integrates a stretchable printable enzyme-based biosensing system and active surface for swipe sampling on different fingers, and is coupled ...

2014
Jing Leng Wen-Min Wang Li-Min Lu Ling Bai Xin-Lan Qiu

In this paper, single-stranded DNA (ss-DNA) is demonstrated to functionalize graphene (GR) and to further guide the growth of PtAu bimetallic nanoparticles (PtAuNPs) on GR with high densities and dispersion. The obtained nanocomposites (PtAuNPs/ss-DNA/GR) were characterized by transmission electron microscopy (TEM), energy-dispersive X-ray spectrometer (EDS), and electrochemical techniques. The...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2013
Xianrui Li Tiankun Ren Na Wang Xueping Ji

An amperometric biosensor for the determination of catechol was developed by immobilizing tyrosinase (tyr) on gold nanoparticles (AuNPs) and a (3-mercaptopropyl)-trimethoxysilane (MPTS) sol-gel three-dimensional network film-modified gold electrode. The AuNPs self-assembled in a sol-gel network provided an excellent microenvironment for an enzymatic reaction between tyrosinase and the substrate...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2008
Zhou-Sheng Yang Wei-Li Wu Xi Chen Yun-Chun Liu

An amperometric horseradish peroxidase (HRP) inhibition biosensor has been substantially constructed by the help of N,N-dicyclohexylcarbodiimide (DCC), N-hydroxysuccinimide (NHS). The preparation steps and the biosensor response to phenylhydrazine were monitored by electrochemical impedance spectroscopy (EIS), cyclic voltammetry, and chronoamperometry. The proposed biosensor could be applied to...

2007
Monika Turek Lothar Ketterer Melanie Claβen Heinz K. Berndt Gereon Elbers Peter Krüger Michael Keusgen Michael J. Schöning

A cyanide biosensor based on a pH-sensitive p-doped electrolyte-insulatorsemiconductor (EIS) structure with an immobilised enzyme (cyanidase) is realised at the laboratory scale. The immobilisation of the cyanidase is performed in two distinct steps: first, the covalent coupling of cyanidase to an N-hydroxysuccinimide(NHS) activated Sepharose gel and then, the physical entrapment of NHS-activat...

2017
Yihao Chen Siyuan Lu Shasha Zhang Yan Li Zhe Qu Ying Chen Bingwei Lu Xinyan Wang Xue Feng

Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an...

2010
LAURA MURESAN SZILVESZTER GÁSPÁR GRAZIELLA TURDEAN IONEL CATALIN POPESCU

In our quest for a simple and fast method to detect glucose in wines, a redox polymer (RP)-based amperometric biosensor was developed. The biosensor consists of glucose oxidase and horseradish peroxidase (as recognition tandem), an Os-based RP (as electron transfer mediator), poly(ethylene glycol) diglycidyl ether (as cross-linking agent), and a graphite electrode (as transducer). Each building...

Journal: :Frontiers in bioscience : a journal and virtual library 2005
Ruiling Fu Jinzhong Xu Yu-Ru Li Yan-Li Wei Jun-Jie Zhu

A titania film with horseradish peroxidase (HRP) was immobilized on indium tin oxide (ITO) electrodes to act as a biosensor of hydrogen peroxide via the self-assembling and sol-gel route. The film was characterized by the atomic functional microscopy, electrochemical and UV-vis spectroscopy methods. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen pero...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید