نتایج جستجو برای: dental alloy

تعداد نتایج: 212737  

2011

Minor problems arising from optimizations by welding of fixed prostheses frameworks can be identified by macroscopic and microscopic visual inspection. The purpose of this study was to highlight the visible discontinuities present in the laser welds of dental Ni-Cr alloys. Ni-Cr base metal alloys designated for fixed prostheses manufacture were selected for the experiments. Using cast plates, p...

2014
Ashu Sharma Rahul Sharma Soorya Poduval

The application of implants for dental and orthopedic surgery has increased rapidly within the past few decades. In craniomaxillofacial surgery, different implant systems have been applied, for example, for dental and bone replacement or osteosynthesis plates and screws. These implants may be made of pure titanium or a titanium alloy, usually titanium-aluminumvanadium (Ti-6Al-4V). The surface c...

Journal: :Dental materials journal 2014
Yuka Kajima Hisashi Doi Atsushi Takaichi Takao Hanawa Noriyuki Wakabayashi

The purpose of this study was to evaluate mechanical properties, surface characteristics and castability of Zr-14Nb dental castings. The mean 0.2% proof and ultimate tensile strengths of Zr-14Nb were approximately 68% and 76% those of Ti-6Al-7Nb, respectively, while they were comparable to Co-29Cr-6Mo. Elongation of Zr-14Nb was the highest of all alloys tested. The hardened reaction layer was f...

Journal: :Brazilian dental journal 2012
João Paulo Lyra e Silva Alfredo Júlio Fernandes Neto Luís Henrique Araújo Raposo Veridiana Resende Novais Cleudmar Amaral de Araujo Luisa de Andrade Lima Cavalcante Paulo Cezar Simamoto Júnior

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and ...

2017
Xiaojing Li Kaili Lin Zuolin Wang

Graphene and its derivatives, including graphene oxide (GO) and reduced graphene oxide (rGO), have been considered as promising candidates in tissue regeneration. However, there is little information about their use as dental implant coating materials. In the present study, we fabricated an rGO coating on Ti6Al4V alloys. Then, the effect of the rGO coating on the growth and osteogenic different...

2011

Minor problems arising from optimizations by welding of fixed prostheses frameworks can be identified by macroscopic and microscopic visual inspection. The purpose of this study was to highlight the visible discontinuities present in the laser welds of dental Ni-Cr alloys. Ni-Cr base metal alloys designated for fixed prostheses manufacture were selected for the experiments. Using cast plates, p...

Journal: :International journal of oral and maxillofacial surgery 2017
M Y Mommaerts

Severe bone atrophy jeopardizes the success of endosseous implants. This technical note aims to present the innovative concept of additively manufactured sub-periosteal jaw implants (AMSJIs). Digital datasets of the patient's jaws and wax trial in occlusion are used to segment the bone and dental arches, for the design of a sub-periosteal frame and abutments in the optimal location related to t...

Journal: :Acta of bioengineering and biomechanics 2014
Edyta Andrysewicz Joanna Mystkowska Jan Ryszard Dąbrowski Rafał Olchowik

This paper describes the results of tests on the influence of human saliva and its substitutes on tribological characteristics of friction pairs. Each pair consists of enamel and one of the following materials: ceramics, the Meridian B2 dental composite, the GK dental amalgam, and Ti-6Al-4V titanium alloy. The saliva substitutes used were prepared using pyrophosphates, xanthan gum, and mucins d...

2011
Surajit Mistry Debabrata Kundu Someswar Datta Debabrata Basu Chidambaram Soundrapandian

BACKGROUND The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS Bioactive glass and hydroxyapatite formulated and prepared...

Journal: :Dental materials journal 2005
Tsuyoshi Kitagawa Yasuhiro Tanimoto Kimiya Nemoto Masahiro Aida

Using finite element method (FEM), this study sought to investigate how the thickness and Young's modulus of cortical bone influenced stress distribution in bone surrounding a dental implant. The finite element implant-bone model consisted of a titanium abutment, a titanium fixture, a gold alloy retaining screw, cancellous bone, and cortical bone. The results showed that von Mises equivalent st...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید