نتایج جستجو برای: cyberknife

تعداد نتایج: 911  

2015
Jacob A. Gersh Benjamin Willett

Traditional CyberKnife (CK) calibration uses TG-51, which requires kQ to be defined using the standard reference condition of 100 cm SSD in a 10 cm × 10 cm field. Since the CK is calibrated using a 6 cm fixed-aperture collimating cone at 80 cm SAD, the BJR-25 method is commonly used to relate circular-field PDDs to square-field PDDs for kQ determination. Using the InCise MLC system, the CK is a...

2017
Shui-Wang Qing Xiao-Ping Ju Yang-Sen Cao Huo-Jun Zhang

BACKGROUND Dose escalation of SBRT for locally advanced pancreatic cancer patients had been reported in several studies in one or three fractions, and phase I protocol was developed to investigate the maximum tolerated dose with CyberKnife for locally advanced unresectable pancreatic cancer patients in five fractions. METHODS The study is designed as a mono-center phase I study. The primary e...

Journal: :Technology in Cancer Research & Treatment 2010

Journal: :International journal of radiation oncology, biology, physics 2008
Jacob Van Dyk

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also d...

2014
Ahmad Nobah Saad Aldelaijan Slobodan Devic Nada Tomic Jan Seuntjens Mohammad Al‐Shabanah Belal Moftah

In this work we compare doses from imaging procedures performed on today's state-of-the-art integrated imaging systems using a reference radiochromic film dosimetry system. Skin dose and dose profile measurements from different imaging systems were performed using radiochromic films at different anatomical sites on a humanoid RANDO phantom. EBT3 film was used to measure imaging doses from a Tom...

2014
Huailing Zhang Guoru Zhao David Djajaputra Yaoqin Xie

PURPOSE To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. METHODS AND MATERIALS Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval) and compensated by the robot. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید