نتایج جستجو برای: curved strut
تعداد نتایج: 20864 فیلتر نتایج به سال:
BACKGROUND Fibrous dysplasia of the proximal femur is a progressive, often recurrent condition of bone that can cause skeletal deformity, fractures, and pain [corrected]. Allogeneic cortical strut grafting to minimize the risk of fracture or as part of fracture treatment is a promising treatment option, but evidence is scarce on the intermediate- to long-term results of this procedure and there...
The objective of this review to be submitted in two independent parts, for steel frames and for RC frames, is to compare their structural performance with respect to the proposed N2-method, and so also of the consequent convenience of using pushover methodology for the seismic analysis of these structures. A preliminary investigation is presented on a pushover analysis used for the seismic perf...
Fifty-six patients who underwent anterior fusion utilizing fibular allograft are reviewed. Thirty-two patients underwent multiple-level anterior cervical discectomy and fusion utilizing fibular strut allograft, and 24 underwent anterior lumbar discectomy and fusion using fibular strut allograft. Cervical surgery was performed via the strut technique of Whitecloud and LaRocca and lumbar surgery ...
PURPOSE To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). METHODS The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent ...
This paper proposes simple semi-phenomenological models to predict the sound absorption efficiency of highly porous polyurethane foams from microstructure characterization. In a previous paper [J. Appl. Phys. 110, 064901 (2011)], the authors presented a 3-parameter semi-phenomenological model linking the microstructure properties of fully and partially reticulated isotropic polyurethane foams (...
BACKGROUND Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut ...
Lattice Boltzmann method is one of computational fluid dynamic subdivisions. Despite complicated mathematics involved in its background, end simple relations dominate on it; so in comparison to the conventional computational fluid dynamic methods, simpler computer programs are needed. Due to its characteristics for parallel programming, this method is considered efficient for the simulation of ...
BACKGROUND In-stent restenosis rates have been closely linked to the wall shear stress distribution within a stented arterial segment, which in turn is a function of stent design. Unfortunately, evaluation of hemodynamic performance can only be evaluated with long term clinical trials. In this work we introduce a set of metrics, based on statistical moments, that can be used to evaluate the hem...
PURPOSE We present a new morphometric measure of trabecular bone microarchitecture, called mean node strength (NdStr), which is part of a newly developed approach called long range node-strut analysis. Our general aim is to describe and quantify the apparent "latticelike" microarchitecture of the trabecular bone network. METHODS Similar in some ways to the topological node-strut analysis intr...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید