نتایج جستجو برای: claw phakic intraocular lens
تعداد نتایج: 67040 فیلتر نتایج به سال:
We report a combination of surgical techniques during Descemet-stripping automated endoithelial keratoplasty and intraocular lens (IOL) exchange in patients with pseudophakic bullous keratopathy and angle-supported anterior chamber IOLs. During this procedure, the anterior chamber IOL is exchanged for a posterior chamber iris-claw IOL enclavated to the posterior iris; the anterior chamber is ke...
PURPOSE To evaluate higher order aberrations and contrast sensitivity after LASIK, implantation of the Verisyse phakic intraocular lens (IOL), and refractive lens exchange with the Array multifocal IOL. METHODS In a prospective, non-randomized case series, LASIK was performed in 20 eyes with the Technolas 217z excimer laser (Bausch & Lomb, Rochester, NY), a Verisyse phakic IOL (AMO Inc, Santa...
PURPOSE To compare the long-term results (9 years) of LASIK in one eye and phakic intraocular lens (implantable contact lens [ICL]) implantation in the fellow eye of the same patient. METHODS A patient with high myopia underwent LASIK with a MEL 60 excimer laser in one eye (spherical equivalent refraction -9.75 diopters [D], 5-mm optical zone with no transition zone) and phakic intraocular le...
PURPOSE To compare the efficacy and outcome of phakic toric implantable collamer lens (TICL) and refractive clear lens extraction with AcrySof Toric intraocular lens (TIOL) implantation for the treatment of myopic astigmatism. PATIENTS AND METHODS This study assessed eyes with myopic astigmatism >-1 D and ≤-4 D with a spherical equivalent >10 D or <10 D if the patients were unsuitable for cor...
PURPOSE To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. METHODS A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed incl...
PURPOSE We report the postoperative results of the Artisan Hyperopia phakic intraocular lens (IOL; model 203W; Ophtec, Groningen, The Netherlands). DESIGN Prospective, nonrandomized trial. PARTICIPANTS Twenty-six eyes of 13 self-selected patients with refractive error ranging from +3.00 to +11.00 diopters (D). INTERVENTION Patients with hypermetropia were implanted with the Artisan Hypero...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید