نتایج جستجو برای: breath holding spells

تعداد نتایج: 45783  

Journal: :Journal of hypertension. Supplement : official journal of the International Society of Hypertension 1990
E O'Brien K O'Malley

As ambulatory blood pressure measurement becomes more widely accepted in hypertension research and in the clinical management of high blood pressure, the number of devices available on the market has increased considerably, reflecting the clinical demand. These devices are expensive, both in terms of capital and running costs. As we rely increasingly on data produced by ambulatory systems, it b...

Journal: :Blood pressure monitoring 2010
Bruce S Alpert

OBJECTIVE We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. METHODS We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed for 85 individuals each. RESULTS The Ambulo 2400 passed both ISO and BHS cr...

Journal: :Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance 1999
P M Jakob M A Griswold R R Edelman W J Manning D K Sodickson

SMASH (SiMultaneous Acquisition of Spatial Harmonics) was recently introduced as a novel rapid-imaging technique. The SMASH technique uses a partially parallel acquisition strategy, using spatial information from a radiofrequency coil array to accelerate imaging. This study constitutes the first application of SMASH to cardiac magnetic resonance imaging. The increased imaging speed provided by ...

Journal: :Hypertension 1995
E O'Brien N Atkins J Staessen

The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any valid...

2006
Wolfgang J. Duschl Peter A. Strittmatter

• The luminosities of the quasars with the largest redshifts indicate that central BH masses of > 10 M⊙ were already present when the Universe was less than 10 years old (Barth et al. 2003). These masses are lower limits as they are based on the assumption that the BHs accrete at their Eddington limit. There is no indication that the (majority of the) sample of highest-redshift-quasar luminosit...

Journal: :Journal of neurosurgical anesthesiology 2006
Dilek Yörükoğlu Zekeriyya Alanoğlu Ufuk Bülent Dilek Ozlem Selvi Can Yüksel Keçik

The aim of this study was to evaluate the incidence of coughing and breath holding in patients undergoing lumbar surgery extubated in prone position, supine position, or supine position with intravenous lidocaine before extubation. About 105 ASA I to II patients undergoing lumbar surgery were extubated in prone position in group P (n = 35), in supine position in group S (n = 35) and in supine p...

Journal: :Medical physics 2002
W G O'Dell M C Schell D Reynolds R Okunieff

Recent advances in Stereotactic Radiosurgery/Conformal Radiotherapy have made it possible to deliver surgically precise radiation therapy to small lesions while preserving the surrounding tissue. However, because of physiologic motion, the application of conformal radiotherapy to extra-cranial tumors is, at present, geared toward slowing the progression of disease rather than obtaining a cure. ...

Journal: :Magnetic resonance in medicine 2009
Peter Kellman Christophe Chefd'hotel Christine H Lorenz Christine Mancini Andrew E Arai Elliot R McVeigh

Cine MRI is used for assessing cardiac function and flow and is typically based on a breath-held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real-time imaging may be used without breath holding or ECG triggering. However, despite the use of rapid imaging sequences and accelerated parallel imaging, real-t...

2017
Nikita Trembach Igor Zabolotskikh

Background The sensitivity of peripheral chemoreflex is a marker of the severity of heart failure and the prognosis of the outcome in these patients. The assessment of chemosensitivity in these patients remains an actual problem. Objective The aim of the study was to explore the relationship between a Breath-Holding Test (BHT) and single-breath carbon dioxide test and to evaluate the reliabil...

Journal: :British journal of diseases of the chest 1969
S Godfrey

EVERY medical student and, indeed, every schoolboy knows that it is possible to hold the breath for a longer time with lungs fully inflated than at a smaller lung volume, and that the breath-holding time can also be prolonged by hyperventilation beforehand. This prolongation is possible because the onset of the unpleasant sensations which arise during breath-holding is delayed. Thus both mechan...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید