نتایج جستجو برای: bone plate

تعداد نتایج: 372779  

Journal: :Development 2004
Dominique Stickens Danielle J Behonick Nathalie Ortega Babette Heyer Bettina Hartenstein Ying Yu Amanda J Fosang Marina Schorpp-Kistner Peter Angel Zena Werb

The assembly and degradation of extracellular matrix (ECM) molecules are crucial processes during bone development. In this study, we show that ECM remodeling is a critical rate-limiting step in endochondral bone formation. Matrix metalloproteinase (MMP) 13 (collagenase 3) is poised to play a crucial role in bone formation and remodeling because of its expression both in terminal hypertrophic c...

Journal: :Bone 2014
Allison R Altman Wei-Ju Tseng Chantal M J de Bakker Beom Kang Huh Abhishek Chandra Ling Qin X Sherry Liu

Daily injections of parathyroid hormone (PTH) are the only FDA-approved anabolic treatment for osteoporosis; however PTH is only clinically approved for treatment periods of up to 24months. To enhance its anabolic effect, combining PTH with anti-resorptive therapy was proposed and expected to maximize the effectiveness of PTH. The current study aimed to elucidate structural mechanisms through w...

2013
Jae Jun Lee Hyoung Joon Park Hyun Gon Choi Dong Hyeok Shin Ki Il Uhm

BACKGROUND Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. METHODS We treated nine patients ...

Journal: :The Journal of Cell Biology 1997
Kin Ming Kwan Michael K.M. Pang Sheila Zhou Soot Keng Cowan Richard Y.C. Kong Tim Pfordte Bjorn R. Olsen David O. Sillence Patrick P.L. Tam Kathryn S.E. Cheah

There are conflicting views on whether collagen X is a purely structural molecule, or regulates bone mineralization during endochondral ossification. Mutations in the human collagen alpha1 (X) gene (COL10A1) in Schmid metaphyseal chondrodysplasia (SMCD) suggest a supportive role. But mouse collagen alpha1 (X) gene (Col10a1) null mutants were previously reported to show no obvious phenotypic cha...

Journal: :Acta of bioengineering and biomechanics 2017
Jiri Marvan Zdenek Horak Miloslav Vilimek Lukas Horny David Kachlik Vaclav Baca

Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simula...

2013
Giuseppe Musumeci Paola Castrogiovanni Carla Loreto Sergio Castorina Karin Pichler Annelie Martina Weinberg

The epiphyseal plate is a hyaline cartilage plate that sits between the diaphysis and the epiphysis. The objective of this study was to determine the impact of an injury in the growth plate chondrocytes through the study of histological morphology, immunohistochemistry, histomorphometry and Western Blot analyses of the caspase-3 and cleaved PARP-1, and levels of the inflammatory cytokines, Inte...

Journal: :Annals of the rheumatic diseases 1987
R W Mellish M M O'Sullivan N J Garrahan J E Compston

Iliac crest trabecular bone volume and structure have been studied in bone biopsy specimens from 48 patients with classical or definite rheumatoid arthritis, none of whom had received steroids. Results were compared with those obtained from healthy controls matched for age and sex. The mean trabecular bone volume in female patients aged 34-50 years was significantly lower than in controls (p le...

Journal: :Compendium of continuing education in dentistry 2015
Stephen J Chu Guido O Sarnachiaro Mark N Hochman Dennis P Tarnow

Immediate implant therapy involving implants placed into intact Type 1 extraction sockets has become a consistent clinical technique. The classification of Type 2 extraction sockets, where the mucosal tissues are present but there is a midfacial osseous dehiscence defect, has been described according to the extent of the buccal bone plate absence. The literature has offered different techniques...

Journal: :Veterinary and comparative orthopaedics and traumatology : V.C.O.T 2008
C Rahal C C Otoni O C M Pereira Júnior A L L Blum L C Vulcano

A Brazilian orthopaedic company designed a stainless steel plate called Synthesis Pengo System (S.P.S.), which has one fixed and one changeable extremity. According to the assembly of the changeable extremity, it is possible to obtain dynamization or neutralization of the fracture site. Since the S.P.S. plate was developed for use in human patients, the aim of this study was to evaluate this sy...

2009
Yngvar Krukhaug Nils R Gjerdet Odd J Lundberg Peer K Lilleng Leiv M Hove

BACKGROUND AND PURPOSE In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different commercially available plates (3 volar and 2 dorsal) with standard K-wire fixatio...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید