نتایج جستجو برای: 3 d conformal radiotherapy

تعداد نتایج: 2281537  

Journal: :Physics in medicine and biology 2006
Ruijie Yang Jianrong Dai Yong Yang Yimin Hu

The purpose of this study is to extend an algorithm proposed for beam orientation optimization in classical conformal radiotherapy to intensity-modulated radiation therapy (IMRT) and to evaluate the algorithm's performance in IMRT scenarios. In addition, the effect of the candidate pool of beam orientations, in terms of beam orientation resolution and starting orientation, on the optimized beam...

Journal: :Radiation Oncology (London, England) 2008
Hans Paul van der Laan Wil V Dolsma John H Maduro Erik W Korevaar Johannes A Langendijk

BACKGROUND The shift from conventional two-dimensional (2D) to three-dimensional (3D)-conformal target definition and dose-planning seems to have introduced volumetric as well as geometric changes. The purpose of this study was to compare coverage of computed tomography (CT)-based breast and boost planning target volumes (PTV), absolute volumes irradiated, and dose delivered to the organs at ri...

2014
Ricardo Cendales Jaider Vásquez Juan Arbelaez Ivan Bobadilla Felipe Torres Armando Gaitan

PURPOSE To compare dosimetric results of the use of RapidArc® with simultaneous integrated boost, sliding window intensity-modulated radiotherapy (IMRT) with simultaneous integrated boost, and conformal radiotherapy with sequential boost in the management of anal canal cancer. METHODS Two patients with squamous cell cancer of the anal canal with compromised inguinal nodes were included. The s...

2006
BAHAR BALTALARLI

it was assumed that, although there were small discrepancies between the plans and all of the doses were under the critical dosages stated for rectum, bladder and femoral heads for each technique, the doses given to the critical organs were higher with the MLC technique. Regarding the late toxicity and the critical organ doses, each of these shaping methods is suitable for the definitive irradi...

Journal: :Tumori 2012
Francesco Deodato Savino Cilla Mariangela Massaccesi Gabriella Macchia Edy Ippolito Luciana Caravatta Vincenzo Picardi Michele Romanella Carlo Di Falco Alessandra Bartollino Vincenzo Valentini Numa Cellini Marco De Spirito Angelo Piermattei Alessio G Morganti

AIMS AND BACKGROUND The aim of this report was to investigate the feasibility in terms of treatment time prolongation of an on-line no-action level correction protocol, based on daily electronic portal image verification. METHODS AND STUDY DESIGN The occupation of a linear accelerator (LINAC) delivering 3-D conformal treatments was monitored for two weeks (from Monday to Friday, 10 working da...

2009
David Maxwell

We investigate the possibility that the conformal and conformal thin sandwich (CTS) methods can be used to parameterize the set of solutions of the vacuum Einstein constraint equations. To this end we develop a model problem obtained by taking the quotient of certain symmetric data on conformally žat tori. Specializing the model problem to a three-parameter family of conformal data we observe a...

Journal: :Physical review letters 2016
Kristan Jensen Andy O'Bannon

A conformal field theory (CFT) in dimension d≥3 coupled to a planar, two-dimensional, conformal defect is characterized in part by a "central charge" b that multiplies the Euler density in the defect's Weyl anomaly. For defect renormalization group flows, under which the bulk remains critical, we use reflection positivity to show that b must decrease or remain constant from the ultraviolet to t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید