نتایج جستجو برای: دزیمتر گرماتاب tld
تعداد نتایج: 1068 فیلتر نتایج به سال:
BACKGROUND A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths - with different number as well as activities of 125I seeds. METHODS The radiation dosimetry of three representative ra...
OBJECTIVE The aim of this work was to determine the radiation dose received by infants from radiographic exposure and the contribution from scatter radiation due to radiographic exposure of other infants in the same room. MATERIALS AND METHODS We retrospectively evaluated the entrance skin doses (ESDs) and effective doses of 23 infants with a gestational age as low as 28 weeks. ESDs were dete...
The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivit...
PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...
مهمترین مزیت دزیمترهای ژلی توانایی منحصر به فرد آنها در تعیین توزیع سهبعدی دز است. دزیمترهای ژلی- پلیمری در حقیقت مونومرهایی هستند که در یک شبکهی ژلاتینی به طور یکنواخت توزیع شدهاند. در اثر پرتودهی، مونومرهای موجود در ژل به پلیمر تبدیل شده و برخی خواص دزیمتر ژلی تغییر میکنند که قابل آشکارسازی است. یکی از این تغییرها، خواص مغناطیسی دزیمتر ژلی- پلیمری است که از طریق تصویربرداری تشدید مغ...
BACKGROUND The effects of spinal implants on dose distribution have been studied for conformal treatment plans. However, the dosimetric impact of spinal implants in stereotactic body radiotherapy (SBRT) treatments has not been studied in spatial orientation. In this study we evaluated the effect of spinal implants placed in sawbone vertebra models implanted as in vivo instrumentations. METHOD...
Neutron individual monitoring is considerably less established than photon individual monitoring. The main difficulty is the impossibility to find a detector that covers the large occupational neutron energy range. All commercial individual monitors have strong energy dependence. Another difficulty is to calibrate an individual neutron monitor in the ISO 21909 established energy operational ran...
سیستم دزیمتری oslاولین بار در سال 1963معرفی و از سال 2005 به عنوان یکی از سیستم های دزیمتری فضایی در مأموریت های مختلف فضایی استفاده شده است. در این پژوهش سعی شده تا برای اولین بار در ایران این سیستم دزیمتری در مقیاس آزمایشگاهی ساخته شود. اساس این تکنیک، پدیده کوانتومی گسیل لومینسانسی است که از طریق تحریک، توسط چشمه نوری حاصل می شود. این سیستم شامل یک ماده دزیمتر osl، بخش اپتیکی و سیستم آشکارسا...
از اوائل دهه اخیر، سیستم کنترل غیرفعال جدید در زمینه کاهش ارتعاشات سازه ها مطرح شده که میراگر مایع هماهنگ شده (tuned liquid damper) یا اختصارا tld نامیده می شود. اساس کار آن بر مبنای استهلاک انرژی وارده به سازه (ناشی ازدیاد، زلزله و...) توسط تلاطم مایع کم عمقی در درون یک یا چند مخزن است که در بالای سازه نصب می گردد. عمق ولزجت مایع و همچنین ابعاد و تعداد تانکها به منظور رسیدن به درصد است...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید