Stergios Lazarinis Johan Kärrholm Nils P Hailer

BACKGROUND AND PURPOSE Hydroxyapatite (HA) is widely used as a coating for uncemented total hip arthroplasty components. This has been suggested to improve implant ingrowth and long-term stability. However, the evidence behind the use of HA coating on femoral stems is ambiguous. We investigated survival of an uncemented, tapered titanium femoral stem that was available either with or without HA...

Journal: :Acta medica 2014
Pavel Šponer Tomáš Kučera Karel Urban David Zítko Daniel Diaz-Garcia Michal Grinac

BACKGROUND Though mid-term survival rates of over 95% in several series have been published, there is still a paucity of related literature regarding the role of vertical stem instability in the osteointegration of fluted tapered stems. This paper presents a comprehensive and prospective assessment on short-term experiences with uncemented modular femoral stem in the treatment of defective femu...

2010
Georg W Omlor Hannah Ullrich Knut Krahmer Alexander Jung Günther Aldinger Peter Aldinger

BACKGROUND AND PURPOSE Variations in hip anatomy limit the femoral canal fit of standard uncemented hip stems. In addition, there are still issues with leg length discrepancy and offset reconstruction, potentially resulting in impingement, dislocation, and wear. Modular stems with different shapes for femoral canal fit and multiple neck options may improve the outcome and reduce complications. ...

Journal: :Orthopedics 2016
Tatsuya Sueyoshi John B Meding Michael E Berend Matthew J Brunsman Merrill A Ritter

An uncemented stem has been used successfully in total hip arthroplasty for 2 decades, and some implants have been updated. The authors have used second-generation uncemented proximal porous coating stems, the Echo Bi-Metric Full Proximal Profile stem (Echo FPP; Biomet, Warsaw, Indiana) and the Echo Reduced Proximal Profile stem (Echo RPP; Biomet). This article reports short-term outcomes with ...

2014
Tobias Lindner Christine Krüger Cornelius Kasch Susanne Finze Wolfram Steens Wolfram Mittelmeier Ralf Skripitz

BACKGROUND Numerous studies have shown reduction of periprosthetic bone mineral density (BMD) after hip replacement. The effect on the whole limb, however, is still unexplored. This study's objective was to analyse the postoperative development of BMD and muscle strength of the limb after total hip replacement (THR) and to determine links between these parameters. METHODS 55 patients, who und...

2014
Olof G Sköldenberg Helene Sjöö Paula Kelly-Pettersson Henrik Bodén Thomas Eisler André Stark Olle Muren

BACKGROUND AND PURPOSE We previously evaluated a new uncemented femoral stem designed for elderly patients with a femoral neck fracture and found stable implant fixation and good clinical results up to 2 years postoperatively, despite substantial periprosthetic bone mineral loss. We now present the medium-term follow-up results from this study. PATIENTS AND METHODS In this observational prosp...

Journal: :Journal of Nippon Medical School = Nippon Ika Daigaku zasshi 2016
Hidemi Kawaji Takuya Uematsu Ryosuke Oba Naoya Hoshikawa Hiroshi Watanabe Shinro Takai

BACKGROUND The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. MATERIALS AND METHODS The study participants included 89 patients who underwent unc...

2018
Minxun Lu Li Min Cong Xiao Yongjiang Li Yi Luo Yong Zhou Wenli Zhang Chongqi Tu

Introduction Currently, it is challenging to treat giant cell tumor (GCT) of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius w...

2015
Tahir Mutlu Duymus Zafer Solak Yusuf Ozturkmen Ibrahim Azboy Serhat Mutlu Mustafa Caniklioglu

BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...

2013
Torben Bæk Hansen Maiken Stilling

BACKGROUND AND PURPOSE Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. PATIENTS AND METHODS In a prospective, parallel-group, randomized patient-blinded clinica...