نتایج جستجو برای: treatment time absorbed dose

تعداد نتایج: 3277747  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1999
A Liu L E Williams G Lopatin D M Yamauchi J Y Wong A A Raubitschek

UNLABELLED An object-oriented software system is described for estimating internal emitter absorbed doses using a set of computer modules operating within a personal computer environment. The system is called the Radionuclide Treatment Planning and Absorbed Dose Estimation System (RTDS). It is intended for radioimmunotherapy applications, although other forms of internal emitter therapy may als...

2013
F Nordström

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4 dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept o...

Hojjat Khalili Marjaneh Mirsadraie Mehdi Silanian toosi Shokoufeh Mohebbi

Introduction: During treatment of breast cancer, Radiotherapy to the Supraclavicular fossa region results in absorption of radiation by the thyroid gland and consequently leads to hypothyroidism in 40% of patients. The aim of this study was to compare thyroid gland radiation absorption during radiotherapy with different anterior-posterior beam radiation of 6-15 and 15-15 MV pho...

2016
Elham Piruzan Mahdi Haghighatafshar Reza Faghihi Seyed Mohammad Entezarmahdi

Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal ra...

2015
Alireza Nikoofar Zohreh Hoseinpour Seied Rabi Mahdavi Hadi Hasanzadeh Mostafa Rezaei Tavirani

BACKGROUND The high-dose-rate (HDR) brachytherapy might be an effective tool for palliation of dysphagia. Because of some concerns about adverse effects due to absorbed radiation dose, it is important to estimate absorbed dose in risky organs during this treatment. OBJECTIVES This study aimed to measure the absorbed dose in the parotid, thyroid, and submandibular gland, eye, trachea, spinal c...

Journal: :iranian journal of radiation research 0
f. tabeie i. neshandar asli s.m. aghamiri k. arbabi

background: annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. we calculated the staff to patient dose equivalent ratio to be used as a phy...

Journal: :Japanese Journal of Radiological Technology 1990

Journal: :iranian journal of radiation research 0
a.a. mowlavi physics department, sabzevar tarbiat moallem university, sabzevar, iran a. afzali physics department, sabzevar tarbiat moallem university, sabzevar, iran n. afzali physics department, imam khomeini university of sabzevar, sabzevar, iran

background: skin cancer can be treated by various methods. electron radiotherapy has been a useful therapeutic modality in the treatment of skin cancers in areas which are difficult to cure by other methods. depth dose distribution of 166ho using varskin2 code is presented in this work. material and methods: depth dose distribution of 166ho was calculated, using varskin2 code by adding of 166ho...

Journal: :Physics in medicine and biology 2000
M Fippel F Nüsslin

Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید