Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-r...
Polycrystalline ammonium dithionate has been examined for its radiation response in the low dose range (<5Gy) using EPR technique. The SO(3)(-) radical ion was detected as a single EPR line with a peak-to-peak derivative width of ca. 0.44mT in irradiated samples and its intensity was found to vary linearly with dose. At equal and moderate settings of microwave power and modulation amplitude amm...
This paper provides an overview of the characteristics of a phenothiazine-mylar dosimeter which can be used as an effective solar UVA exposure assessment tool. This dosimeter is sensitive to UVA wavelengths (315-400 nm); its performance has been characterized in a series of tests such as (a) UVA exposure response (dose-response), (b) temperature stability of the response, (c) impact of long ter...
Rubisco activase plays an important role in the regulation of CO(2) assimilation. However, it is unknown how activase regulates photosystem II (PSII) photochemistry. To investigate the effects of Rubisco activase on PSII photochemistry, we obtained transgenic tobacco (Nicotiana tabacum) plants with 50% (i7), 25% (i28), and 5% (i46) activase levels as compared to wild type plants by using a gene...
Abstract Three different dosimetry systems were prepared based on diphenyl thiocarbazone (DTH) dye: polymer films made with, poly(vinyl alcohol), DTH liquid dosimeter and gel dosimeter. All the received several gamma doses. The three analyzing by UV–Vis spectrophotometery before after irradiation. effective dose range in linear part of these is between 1–10 kGy, 0.3–2 50–200 Gy. dosimeters reli...
Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...
Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...
Background and Aim: The basic aim in radiography is to scan a clear image from the body organs, but the issue of the patient's protection against the harmful effects of ionizing radiation should never be neglected.The present study aimed at calculating the received drug to the perigonadic areas during radiography. Materials and Methods: In the current study thermoluminescence dosimeter w...
Quality-control dosimetry is important to the routine operation of a radiation processing facility. For many applications this dosimetry must be traceable to a national primary standard. After irradiation at an industrial facility, National Institute of Standards and Technology (NIST)-supplied transfer dosimeters are certified by measurement and dose interpolation from the NIST calibration curv...