نتایج جستجو برای: strut mechanisms
تعداد نتایج: 538701 فیلتر نتایج به سال:
An investigation has been made of the potential of pulsed transient thermography for identifying the location of fixtures beneath aircraft skins to facilitate accurate automated assembly operations. Experimental studies have been made of 1.6mm thick aluminium skins and both 2mm and 4mm thick carbon fibre reinforced plastic (CFRP) composite skins over both aluminium and composite struts, represe...
s w t o t n t b w o the Editor: Presently, occurrence of late stent thrombosis (LST) fter drug-eluting stent implantation is a major clinical concern. lthough LST is an infrequent complication, LST can lead to erious results. A long-term follow-up study revealed recently that ST occurs at a constant rate of 0.6%/year for up to 3 years after rug-eluting stent implantation (1). Regarding patholog...
BACKGROUND Fibrous dysplasia of the proximal femur is a progressive, often recurrent condition of bone that can cause skeletal deformity, fractures, and pain [corrected]. Allogeneic cortical strut grafting to minimize the risk of fracture or as part of fracture treatment is a promising treatment option, but evidence is scarce on the intermediate- to long-term results of this procedure and there...
The objective of this review to be submitted in two independent parts, for steel frames and for RC frames, is to compare their structural performance with respect to the proposed N2-method, and so also of the consequent convenience of using pushover methodology for the seismic analysis of these structures. A preliminary investigation is presented on a pushover analysis used for the seismic perf...
Fifty-six patients who underwent anterior fusion utilizing fibular allograft are reviewed. Thirty-two patients underwent multiple-level anterior cervical discectomy and fusion utilizing fibular strut allograft, and 24 underwent anterior lumbar discectomy and fusion using fibular strut allograft. Cervical surgery was performed via the strut technique of Whitecloud and LaRocca and lumbar surgery ...
PURPOSE To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). METHODS The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent ...
This paper proposes simple semi-phenomenological models to predict the sound absorption efficiency of highly porous polyurethane foams from microstructure characterization. In a previous paper [J. Appl. Phys. 110, 064901 (2011)], the authors presented a 3-parameter semi-phenomenological model linking the microstructure properties of fully and partially reticulated isotropic polyurethane foams (...
BACKGROUND Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید