نتایج جستجو برای: steel beam
تعداد نتایج: 191338 فیلتر نتایج به سال:
steel structures are usually built with some defects. according to the standard building codes, the central axes of the bracing members should go through the beam-column joints, however, in most of the braced steel structures, bracing members are unintentionally connected eccentrically. this paper presents a numerical investigation on performance analysis of cbfs (concentrically braced frames) ...
corrosion of reinforcing steel and other embedded metals is the main cause of severe deterioration in reinforced concrete structures which subsequently imposes adverse effects on ultimate and serviceability limit state performance of the whole structure. in this paper, a new corrosion detection method for reinforced concrete beams, based on wavelet analysis is presented. to evaluate the capabil...
Moment resisting frames as one of the conventional lateral load resisting systems in buildings suffer from some limitations including code limitations on minimum span-to-depth ratio to ensure the formation of plastic hinges with adequate length at beam ends. According to seismic codes, in ordinary steel moment resisting frames the minimum span-to-depth ratios should be limited to 5 and in speci...
This paper draws together some important lessons from a compartment fire test conducted by BRE in the full-scale eight storey steel building at Cardington. The experiment is briefly described, and the main structural observations are highlighted. A numerical structural model of the fire compartment, using the nonlinear analysis program ADAPTIC, is then discussed. The numerical analysis employs ...
Reinforced concrete beams are normally designed as under-reinforced to provide ductile behaviour at failure i.e. the tensile moment of resistance, Mt(0), is less than the moment of resistance of the compressive zone, Mc. Since it is well established that the steel in reinforced concrete beams is prone to corrosion, the residual flexural strength is normally the main concern of asset managers. H...
The behavior of corroded steel–concrete composite beams under hogging moment was studied by experimental investigation and theoretical analysis. A total of eight specimens, six of which had corroded shear studs, were tested. The corrosion rate of studs ranged from 0 to approximately 50%. The constant-current accelerated corrosion method was adopted to accelerate the corrosion process. The loadi...
The use of Fiber Reinforced Polymer (FRP) reinforcement is a practical alternative to conventional steel rebars in concrete structures subjected to aggressive environments. The solution is attractive for bridge deck and rail applications, as it eliminates corrosion of the steel reinforcement, which is the major instrument of degradation. Due to the peculiar physical and mechanical characteristi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید