نتایج جستجو برای: rubella antibody titer

تعداد نتایج: 179186  

Journal: :Archives of disease in childhood 1983
C S Hosking C Pyman B Wilkins

We describe a laboratory test which is useful in determining whether deafness is due to intrauterine rubella. The study group consisted of 8 deaf patients with proved intrauterine rubella, 12 patients with familial deafness, and 17 controls. Blood was taken at time 0 from all of them. All the deaf children and 5 controls were immunised and further blood samples taken at 2 and 6 weeks. Each bloo...

2015
Ai Hori Koji Wada Derek R. Smith Toshiyuki Ojima

BACKGROUND In 2013 a rubella outbreak occurred among Japanese people of working-age which resulted in 14,357 reported cases. The Japanese government subsequently recommended voluntary vaccination or rubella antibody testing for young women (15-49 years of age) who were planning to conceive and for adult men, children, and other persons in potential contact with pregnant women at home. However, ...

Journal: :Nephron. Clinical practice 2013
Byung Ha Chung Jeong Uk Lim Yaeni Kim Ji-Il Kim In Sung Moon Bum Soon Choi Cheol Whee Park Yong-Soo Kim Chul Woo Yang

BACKGROUND/AIMS We investigated the impact of the baseline anti-A/B antibody titer on the clinical outcome in ABO-incompatible kidney transplantation (IKT). METHODS We included 183 patients who had undergone KT (40 ABO IKT and 143 ABO-compatible KT). Eight patients with a baseline titer of ≥1:512 were assigned to the high-titer group and 32 patients with a baseline titer of ≤1:256 were assign...

Journal: :Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin 2015
C Giambi A Filia M C Rota M Del Manso S Declich G Nacca E Rizzuto A Bella

In accordance with the goal of the World Health Organization Regional Office for Europe, the Italian national measles and rubella elimination plan aims to reduce the incidence of congenital rubella cases to less than one case per 100,000 live births by the end of 2015. We report national surveillance data for congenital rubella and rubella in pregnancy from 2005 to 2013. A total of 75 congenita...

Journal: :Clinical chemistry 1991
H Reiber P Lange

Specific antibody synthesis in brain could be detected with maximal sensitivity by combining an advanced enzyme immunoassay with a sophisticated evaluation method that involves calculating the ratio between the cerebrospinal fluid (CSF)/serum quotients for specific antibodies (Qspec) and total IgG (QIgG). This Antibody Index (AI = Qspec/QIgG) discriminates between a blood-derived and a patholog...

Journal: :Journal of clinical pathology 1984
J Hodgson P Morgan-Capner

A commercial M antibody capture ELISA kit ( Rubenz M) for the detection of rubella specific IgM was evaluated in comparison with M antibody capture radioimmunoassay. A total of 248 sera were evaluated, including sera from cases of primary postnatal rubella, congenital rubella, infectious mononucleosis, and sera which contained rheumatoid factor. No false positive results were obtained but two h...

Journal: :Eastern Mediterranean health journal = La revue de sante de la Mediterranee orientale = al-Majallah al-sihhiyah li-sharq al-mutawassit 2009
E T Abdul-Karim N Abdul-Muhymen M Al-Saadie

The seroprevalences of Chlamydia trachomatis and rubella IgG antibodies were measured in women with full-term deliveries (n = 198) and with abortion (n = 79) in a hospital in Baghdad city, Iraq. Positive rubella antibody titres were found in 42.9% of mothers with full-term deliveries and 34.2% with abortion. C. trachomatis infection was found in 13.6% of mothers with full-term deliveries and 6....

Journal: :The Journal of hygiene 1977
M Clarke J Boustred V Seagroatt G C Schild

The use of a single-radial-haemolysis technique for the detection of antibody to rubella virus is described. The single-radial-haemolysis test was compared with the standard HI methods for the detection of antibody to rubella virus. A close correlation between the two methods was observed in a survey of over two thousand serum samples and the study indicated that single-radial-haemolysis was hi...

Journal: :Journal of clinical pathology 1981
J B Kurtz A Malic

A sensitive method for detecting rubella IgM antibody, the first step of which is the attachment of the serum IgM to a solid phase, is described. Specific IgM antibody was found in all 52 people with acquired rubella in the early convalescent period, in all 38 infants with congenital rubella examined in the first seven months of life, and in 23 of 26 people immunised one to four months before t...

Journal: :The Journal of infectious diseases 2004
Mark S Dine Sonja S Hutchins Ann Thomas Irene Williams William J Bellini Stephen C Redd

Because measles-specific antibody titer after vaccination is lower than after natural infection, there is concern that vaccinated persons may gradually lose protection from measles. To examine the persistence of vaccine-induced antibody, participants of a vaccine study in 1971, with documentation of antibody 1-7 years after vaccination, were followed up in 1997-1999 to determine the presence an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید