نتایج جستجو برای: pvc membrane electrode
تعداد نتایج: 452869 فیلتر نتایج به سال:
A cobalt(II) ion-selective membrane sensor has been fabricated from a poly vinyl chloride (PVC) matrix membrane containing a new oxime compound (oxime of 1-(2-oxocyclohexyl)-1,2-cyclohexanediol, OXCCD) as a neutral carrier, sodium tetraphenyl borate (NaTPB) as an anionic excluder and o-nitrophenyloctylether (o-NPOE) as a plasticizing solvent mediator. The membrane sensor exhibits a linear poten...
A poly(vinyl chloride)-based membrane of 3,4:11,12-dibenzo-1,6,9,14-tetraazacyclohexadecane with sodium tetraphenyl borate (NaTPB) as an anion excluder and dibutylphthalate (DBP), dibutyl(butyl)phosphonate (DBBP), tris(2-ethylhexyl)phosphate (TEHP) and tributyl phosphate (TBP) as a plasticizing solvent mediator was prepared and investigated as a Cd2+-selective electrode. The best performance wa...
A Cadmium (II) ion-selective electrode (ISE) based on Thia polymeric crown ether (SPCE-Cd2+) as a membrane carrier in PVC matrix was successfully built for the determination of Cd2+ ions. Using Dimethyl phthalate (DMP) plasticizer, showed Nernstian liner response spanning range 1*10-1 to 1*10-7 M with slope (28) ±2 mV per decade charge and detection limit 1*10-9 M. The sensor has 10-second time...
Novel highly selective potentiometric sensor based on aquadichloro(E)−2-((1-(thiophen-2-yl)ethylidene)-amino)phenol manganese(II)trihydrate as an anion carrier. The thiocayanate electrode displayed a very high selectivity compared with others inorganic anions. Different sensors plasticized PVC membranes have been investigated. construction containing different amounts of ionophore and without a...
New ranitidine hydrochloride (RaCl)-selective electrodes of the conventional polymer membrane type are described. They are based on incorporation of ranitidine-tetraphenylborate (Ra-TPB) ion-pair or ranitidine-phosphotungstate (RaPT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphthalate (DOP) or dibutylphthalate (DBP). The electrodes are fully characterized in...
We report the first clinical application of electrocardiographic imaging (ECGI), a new, noninvasive imaging modality for arrhythmias, in an athlete with focal ventricular tachycardia (VT) originating from a left ventricular (LV) diverticulum. A reconstructed map of the epicardial activation sequence during a single premature ventricular complex (PVC) of an identical QRS morphology to the clinic...
potentiometric investigation on {h2o+nano3+peg1500} mixtures were made at t=308.15k, using electrochemical cells with two ion-selective electrodes, (na+ glass) as the cation ion-selective electrode against (no3- solvent-polymer pvc) as the anion ion-selective electrode. the mean ionic activity coefficients of nano3 were measured at different concentrations of nano3 and peg. maximum concentrati...
This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of c...
Innovation in potentiometry: 3D-printed polylactic acid-based ion-selective bulk electrode membranes
Abstract Although ion-selective membrane-based potentiometric sensors have already proved their analytical performance in several fields of life, applicability is still limited practice. Biodegradable, ionic additive-free, polylactic acid-based bulk electrode membrane matrix containing various environmentally friendly polyethylene glycol derivatives as plasticizer was developed for the first ti...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید