نتایج جستجو برای: purity germanium
تعداد نتایج: 24042 فیلتر نتایج به سال:
A search of neutrino magnetic moment was carried out at the Kuo-Sheng Nuclear Power Station at a distance of 28 m from the 2.9 GW reactor core. With a high purity germanium detector of mass 1.06 kg surrounded by scintillating NaI(Tl) and CsI(Tl) crystals as anti-Compton detectors, a detection threshold of 5 keV and a background level of 1 kg(-1) keV(-1) day(-1) at 12-60 keV were achieved. Based...
The beam energy measurement system is significant and profit for both BES-III detector and BEPC-II accelerator. The detection of the high energy scattering photons is realized by virtue of the Compton backscattering principle. Many advanced techniques and precise instruments are employed to acquire the highly accurate measurement of positron/electron beam energy. During five years’ running peri...
We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an ar...
South coast of India is known as the high-level background radiation area (HBRA) mainly due to beach sands that contain natural radionuclides as components of the mineral monazite. The rich deposit of monazite is unevenly distributed along the coastal belt of Tamil Nadu and Kerala. An HBRA site that laid in 2×7 m along the sea was found in the beach of Chinnavillai, Tamil Nadu, where the maximu...
Positron annihilation spectroscopy is a sensitive probe for studying the electronic structure of defects in solids. The high-momentum part of the Doppler-broadened spectra can be used to distinguish different elements at the annihilation site. This can be achieved by using a twodetector coincidence system, which reduces the peak to background ratio dramatically. The coincident events have to be...
The Ge(1/2) metastable states decay with a very characteristic signature which allow them to be tagged event-by-event. Studies were performed using data taken with a high-purity germanium detector in a low-background laboratory near a nuclear power reactor core where ν̄e-flux was 6.4× 10 12 cms. The measured average and equilibrium production rates of Ge(1/2) were (8.7± 0.4) and (6.7± 0.3) kgday...
This study aimed to evaluate the residual radioactivity in mice induced by neutron irradiation with an accelerator-based boron neutron capture therapy (BNCT) system using a solid Li target. The radionuclides and their activities were evaluated using a high-purity germanium (HP-Ge) detector. The saturated radioactivity of the irradiated mouse was estimated to assess the radiation protection need...
We report on the first experimental demonstration of Compton imaging of gamma rays with a single coaxial high-purity germanium (HPGe) detector. This imaging capability is realized by two-dimensional segmentation of the outside contact in combination with digital pulse-shape analysis, which enables to image gamma rays in 4p without employing a collimator. We are able to demonstrate the ability t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید