نتایج جستجو برای: pcl peg pcl

تعداد نتایج: 19930  

2013
Ronald Sabo Liwei Jin Nicole Stark Rebecca E. Ibach

Polycaprolactone (PCL) filled with microcrystalline cellulose (MCC), wood flour (WF), or both were characterized before and after exposure to various environmental conditions for 60 days. PCL/WF composites had the greatest tensile strength and modulus compared to neat PCL or PCL composites containing MCC. Electron microscopy indicated better adhesion between WF particles and PCL than between MC...

2009
Lin Mei Yi Zheng Dongye Yang Hongli Chen Hongfan Sun Kexin Liu Zhen Li Laiqiang Huang

Multidrug resistance (MDR) in tumor cells is a significant obstacle to the success of chemotherapy in many cancers. The purpose of this research is to test the possibility of docetaxel-loaded poly (e-caprolactone)/Pluronic F68 (PCL/Pluronic F68) nanoparticles to overcome MDR in docetaxel-resistance human breast cancer cell line. Docetaxel-loaded nanoparticles were prepared by modified solvent d...

2014
Han-Tsung Liao Yo-Yu Chen Yu-Ting Lai Ming-Fa Hsieh Cho-Pei Jiang

The study described a novel bone tissue scaffold fabricated by computer-aided, air pressure-aided deposition system to control the macro- and microstructure precisely. The porcine bone marrow stem cells (PBMSCs) seeded on either mPEG-PCL-mPEG (PCL) or mPEG-PCL-mPEG/hydroxyapatite (PCL/HA) composite scaffold were cultured under osteogenic medium to test the ability of osteogenesis in vitro. The ...

Journal: :The American journal of sports medicine 2015
Christopher M LaPrade David M Civitarese Matthew T Rasmussen Robert F LaPrade

The posterior cruciate ligament (PCL) is recognized as an essential stabilizer of the knee. However, the complexity of the ligament has generated controversy about its definitive role and the recommended treatment after injury. A proper understanding of the functional role of the PCL is necessary to minimize residual instability, osteoarthritic progression, and failure of additional concomitant...

2012
Ning Han Jed K. Johnson Patrick A. Bradley Kunal S. Parikh John J. Lannutti Jessica O. Winter

Hydrogels, electrospun fiber mats (EFMs), and their composites have been extensively studied for tissue engineering because of their physical and chemical similarity to native biological systems. However, while chemically similar, hydrogels and electrospun fiber mats display very different topographical features. Here, we examine the influence of surface topography and composition of hydrogels,...

2012
Elham Khodaverdi Ali Golmohammadian Seyed Ahmad Mohajeri Gholamhossein Zohuri Farnaz Sadat Mirzazadeh Tekie Farzin Hadizadeh

Traditional drug delivery systems which are based on multiple dosing regimens usually pose many disadvantages such as poor compliance of patients and drug plasma level variation. To overcome the obstacles of traditional drug formulations, novel drug delivery system PCL-PEG-PCL hydrogels have been purposed in this study. Copolymers were synthesized by rapid microwave-assisted and conventional sy...

2015
Yu-Shu Lai Wen-Chuan Chen Chang-Hung Huang Cheng-Kung Cheng Kam-Kong Chan Ting-Kuo Chang Gayle E. Woloschak

Surgical reconstruction is generally recommended for posterior cruciate ligament (PCL) injuries; however, the use of grafts is still a controversial problem. In this study, a three-dimensional finite element model of the human tibiofemoral joint with articular cartilage layers, menisci, and four main ligaments was constructed to investigate the effects of graft strengths on knee kinematics and ...

2015
Christian Owesen Einar Andreas Sivertsen Lars Engebretsen Lars-Petter Granan Asbjørn Årøen

BACKGROUND Reports on outcome after posterior cruciate ligament (PCL) reconstruction often contain both isolated PCL and combined knee ligament injuries. This makes it difficult to conclude on the outcome after reconstruction of isolated PCL injuries. PURPOSE To investigate the outcome after PCL reconstruction in patients with an isolated PCL injury and to compare this with the outcome of pat...

2012
Alison J. King Qunli Deng Randy Tyson Jonathan C. Sharp Jarod Matwiy Boguslaw Tomanek Jeff F. Dunn

Open-bore MRI scanners allow joint soft tissue to be imaged over a large, uninterrupted range of flexion. Using an open-bore scanner, 3D para-sagittal images of the posterior cruciate ligament (PCL) were collected from seven healthy subjects in unloaded, recumbent knee extension and flexion. PCL length was measured from one 2D MRI slice partition per flexion angle, per subject. The anterior sur...

2014
Rajendra K. Singh Kapil D. Patel Jae Ho Lee Eun-Jung Lee Joong-Hyun Kim Tae-Hyun Kim Hae-Won Kim

Magnetic nanofibrous scaffolds of poly(caprolactone) (PCL) incorporating magnetic nanoparticles (MNP) were produced, and their effects on physico-chemical, mechanical and biological properties were extensively addressed to find efficacy for bone regeneration purpose. MNPs 12 nm in diameter were citrated and evenly distributed in PCL solutions up to 20% and then were electrospun into nonwoven na...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید