نتایج جستجو برای: osem reconstruction

تعداد نتایج: 123248  

2008
Mohsen Hajizadeh Seyed Rasoul Zakavi Maryam Naji

Introduction: Ordered subset expectation maximization (OSEM), is an effective iterative method for SPECT image reconstruction. The aim of this study is the evaluation of the role of system matrix in OSEM image reconstruction method using four different physical beam radiation models with three detection configurations. Methods: SPECT was done with an arc of 180 degree in 32 projections after in...

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

2014
Pawel Markiewicz Kris Thielemans Ninon Burgos Richard Manber Jieqing Jiao Anna Barnes David Atkinson Simon R Arridge Brian F Hutton Sébastien Ourselin

Centre for Medical Image Computing, University College London, London, UK Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain op...

Amirhosein Vejdani Mahdi Reza Emadzadeh Ramin Sadeghi, Seyed Rasoul Zakavi, Vahid Reza Dabbagh Kakhki,

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

Journal: :Methods 2021

This work demonstrates how computational and physical modelling of the positron emission tomography (PET) image acquisition process for a state-of-the-art integrated PET magnetic resonance imaging (PET-MR) system can produce images comparable to manufacturer. The GE SIGNA PET/MR scanner is manufactured by General Electric has time-of-flight (TOF) capabilities about 390 ps. All software developm...

Journal: :Annals of nuclear medicine 2015
Takafumi Taniguchi Go Akamatsu Yukiko Kasahara Katsuhiko Mitsumoto Shingo Baba Yuji Tsutsui Kazuhiko Himuro Shohei Mikasa Daisuke Kidera Masayuki Sasaki

OBJECTIVE The aim of this study was to evaluate the effect of the point spread function (PSF) and time of flight (TOF) on PET/CT images of overweight patients in relation to the iteration number and the acquisition time. METHODS This study consisted of a phantom study and a clinical study. The NEMA IEC body phantom and a 40 cm diameter large phantom (LG phantom) simulating an overweight patie...

Journal: :Applied Mathematics and Computer Science 2011
Damian Borys Katarzyna Szczucka-Borys Kamil Gorczewski

A method for system matrix calculation in the case of iterative reconstruction algorithms in SPECT was implemented and tested. Due to a complex mathematical description of the geometry of the detector set-up, we developed a method for system matrix computation that is based on direct measurements of the detector response. In this approach, the influence of the acquisition equipment on the image...

Journal: :Nuclear medicine communications 2015
Ceri E Ashton Susan C Doyle Stewart Redman Richard Graham Gordon J Taylor Martyn J Evans

PURPOSE In order to locally validate the technique, a retrospective review of a cohort of randomly selected single-photon emission computed tomography (SPECT) bone scans reconstructed with ordered subsets expectation maximization (OSEM) and Evolution for Bone was undertaken. MATERIALS AND METHODS Thirty consecutive bone SPECT patient data sets (17 spine, nine pelvis, and four spine and pelvis...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید