A radiotheraphy skin dose profile can be obtained with radiochromic film. The central axis skin dose relative to Dmax for a 10 x 10 cm2 field size was found to be 22%, 17% and 15.5% for 6 MV, 10 MV and 18 MV photon beams. Peripheral dose increased with increasing field size. At 10 MV the skin dose 2 cm outside the geometric field edge was measured as 6%, 10% and 17% for 10 x 10 cm2, 20 x 20 cm2...
ntroduction: monte carlo simulation is the most accurate method of simulating radiation transport and predicting doses at different points of interest in radiotherapy. a great advantage of the monte carlo method compared to the deterministic methods is the ability to deal accurately with any complex geometry. its disadvantage is the extremely long computing time r...
background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...
PURPOSE Flattening filter free (FFF) beams in radiotherapy have advantages such as shorter treatment delivery time and lower out-of-field dose compared with conventional flattened beams. This study investigates in detail the skin dose induced by FFF beams from a TrueBeam accelerator (Varian Medical Systems, Palo Alto, CA) using Monte Carlo method. METHODS Phase space files generated using rea...
Purpose: A method for determination of effective transmission factors of the Varian Enhanced Dynamic Wedge (EDW) is investigated. Methods and Material: The model assumes that the EDW factor equals the fraction of monitor units delivered to the geometrical center of the beam. This ”MU fraction approximation” is verified by comparing its predictions with measurements of a series of symmetric and ...
Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...
introduction radiotherapy planning systems require many percentage depth dose (pdd) and profile measurements and there are various dosimeters that can be used to obtain these scans. as dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (efd) in these fields is of interest. the aim of this work was to investigate the ...
Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high...
background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...