Journal: :Physics in medicine and biology 1998
M J Butson P K Yu P E Metcalfe

A radiotheraphy skin dose profile can be obtained with radiochromic film. The central axis skin dose relative to Dmax for a 10 x 10 cm2 field size was found to be 22%, 17% and 15.5% for 6 MV, 10 MV and 18 MV photon beams. Peripheral dose increased with increasing field size. At 10 MV the skin dose 2 cm outside the geometric field edge was measured as 6%, 10% and 17% for 10 x 10 cm2, 20 x 20 cm2...

Journal: :iranian journal of medical physics 0
m. t. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. m. momen nezhad ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran h. saberi ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran m. h. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. a. hashemian assistant professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. r. salek assistant professor, radiation oncology dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran.

ntroduction:  monte  carlo  simulation  is  the  most  accurate  method  of  simulating  radiation  transport  and  predicting doses at different points of interest in radiotherapy. a great advantage of the monte carlo method  compared  to  the  deterministic  methods  is  the  ability  to  deal  accurately  with  any  complex  geometry.  its  disadvantage is the extremely long computing time r...

Journal: :iranian journal of radiation research 0
s. abdollahi reza radiotherapy oncology center, mashhad, iran m. mohammadi department of medical physics, hamadan university of medical science, hamadan, iran a. ebrahimzadeh pezeshki reza radiotherapy oncology center, mashhad, iran z. alizadeh reza radiotherapy oncology center, mashhad, iran

background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...

Journal: :Medical physics 2012
G Zhang K Javedan E Moros K Latifi V Feygelman H Lee Moffitt

PURPOSE Flattening filter free (FFF) beams in radiotherapy have advantages such as shorter treatment delivery time and lower out-of-field dose compared with conventional flattened beams. This study investigates in detail the skin dose induced by FFF beams from a TrueBeam accelerator (Varian Medical Systems, Palo Alto, CA) using Monte Carlo method. METHODS Phase space files generated using rea...

2003
J. E. Salk E. M. Röttinger

Purpose: A method for determination of effective transmission factors of the Varian Enhanced Dynamic Wedge (EDW) is investigated. Methods and Material: The model assumes that the EDW factor equals the fraction of monitor units delivered to the geometrical center of the beam. This ”MU fraction approximation” is verified by comparing its predictions with measurements of a series of symmetric and ...

Khadijeh Hosseini Nahid Chegeni

  Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...

Journal: :iranian journal of medical physics 0
mohammad amin mosleh-shirazi 1- center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, iran 2- physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran sareh karbasi physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran reza faghihi department of medical radiation and radiation research center, school of mechanical engineering, shiraz university, shiraz, iran

introduction radiotherapy planning systems require many percentage depth dose (pdd) and profile measurements and there are various dosimeters that can be used to obtain these scans. as dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (efd) in these fields is of interest. the aim of this work was to investigate the ...

Journal: :Physics in medicine and biology 2011
Youcef El-Mohri Larry E Antonuk Qihua Zhao Richard B Choroszucha Hao Jiang Langechuan Liu

Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high...

Journal: :iranian journal of radiation research 0
k.n. esnaashari department of medical physics tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics tehran university of medical sciences, tehran, iran h. gharaati department of medical physics tehran university of medical sciences, tehran, iran m. shahriari department of medical radiation, shahid beheshti university, tehran, iran

background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...