نتایج جستجو برای: monte carlo dosimetry

تعداد نتایج: 79689  

ژورنال: کومش 2019
Jadidi , Majid , Rajabi , Hossein , Tajik-mansoury , Mohammad Ali, Taleshi Ahangari , Hadi ,

Introduction: Now day Ionizing radiation has found increasing applications in cancer treatment. However, in the treatment different kinds and size of tumors especially metastatic and small size tumors, conventional methods of external radiation therapy are not common. In radionuclide therapy, the use of monoclonal antibodies has made it possible to achieve maximum dose to small size tumor and m...

Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...

Journal: :iranian journal of radiation research 0
m. zehtabian radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran s. sina radiation research center and radiation medicine department, school of engineering, shiraz university, shiraz, iran

background: iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. dosimetric parameters of brachytherapy sources should be determined according to aapm tg-43u1 recommendations before clinical use. monte carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. materials and methods: dosimetric parameters (dos...

Hamid Shahbandarzadeh, Khodakaram Salimifard Reza Moghdani

In this paper, the pricing of a European call option on the underlying asset is performed by using a Monte Carlo method, one of the powerful simulation methods, where the price development of the asset is simulated and value of the claim is computed in terms of an expected value. The proposed approach, applied in Monte Carlo simulation, is based on the Black-Scholes equation which generally def...

Journal: :Brachytherapy 2014
Joshua L Reed Mark J Rivard John A Micka Wesley S Culberson Larry A DeWerd

PURPOSE To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of a new elongated (103)Pd brachytherapy source through both experimental measurements and Monte Carlo (MC) simulations. Measured and MC-calculated dose distributions were used to determine the American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters for t...

Journal: :Archives of ophthalmology 2010
Scott C N Oliver Min Y Leu John J DeMarco Philip E Chow Steve P Lee Tara A McCannel

OBJECTIVE To demonstrate attenuation of radiation from iodine 125 ((125)I) to intraocular structures using liquid vitreous substitutes. METHODS Four candidate vitreous substitutes were tested for attenuation using empirical measurement and theoretical calculation. In vitro and ex vivo cadaveric dosimetry measurements were obtained with lithium fluoride thermoluminescent dosimeters to demonstr...

الهی, مهدی, مهدوی, سید ربیع, هاشمی, بیژن,

Background and purpose: The human body is composed of various inhomogenous tissues with a variety of physical and radiological properties. These inhomogeneities could change isodose distributions, increase the probability of geometric errors, and eventually lead to missing of the target irradiation or incorrect isodose coverage in conformal radiation therapy (CRT) due to the uncertainties resul...

Ali Soleymani Meigooni Reza Faghihi, Sedigheh Sina

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

Journal: :Physics in medicine and biology 2016
J E Lye D J Butler C P Oliver A Alves J Lehmann F P Gibbons I M Williams

Dosimetry protocols for external beam radiotherapy currently in use, such as the IAEA TRS-398 and AAPM TG-51, were written for conventional linear accelerators. In these accelerators, a flattening filter is used to produce a beam which is uniform at water depths where the ionization chamber is used to measure the absorbed dose. Recently, clinical linacs have been implemented without the flatten...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید