نتایج جستجو برای: membrane condenser

تعداد نتایج: 391156  

2013
N. Sheets Mingsheng Liu

Although water-cooled chillers are more energy efficient than air-cooled chillers, a majority of chilled water systems use air-cooled chillers. In cold weather climates, air-cooled chillers are capable of functioning in low ambient temperatures with few operational concerns, where as water-cooled chiller systems must be equipped to prevent cooling tower freezing. The integrated chiller system a...

2015
Y. Y. Liang C. C. Liu C. Z. Li J. P. Chen

Flat tube heat exchangers with louvered fins were applied in order to meet the performance requirements and compactness in automotive air conditioning systems. Experimental and simulation study focusing on the air side thermal hydraulic performance of automotive heat exchangers were performed in this article. Test results showed that the heat capacity of a condenser with 5.4 mm height louvered ...

2017
In-Bok Lee Seunghee Park

As part of a preliminary hazard analysis for a new phenol plant, the results of a hazard and operability study (HAZOP) conducted in the initial stages of the project design were re-evaluated due mechanical failure detected during the test operation. Out of the possible mechanical defects for the crude phenol column (CPC), the fact that the lowest risk grade was given to the column without consi...

2001
Kirk Yerkes Kenneth Pettigrew Dorian Liepmann Brian Smith

A planar, silicon mini capillary pumped loop (CPL) was designed, built, and tested using recent MEMS technology to provide integral cooling and temperature control for electronics. This design featured three silicon fusion bonded wafers incorporating an evaporator, condenser, liquid line and vapor line, all of which were dry plasma etched. Grooves were etched in the condenser and evaporator to ...

Journal: :The Journal of the Acoustical Society of America 2006
Allan J Zuckerwar G C Herring Brian R Elbing

A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone ...

2010
Arnab Ganguly A Venkattraman Alina A. Alexeenko

Freeze-drying is a low-pressure, low-temperature condensation pumping process widely used in the manufacture of pharmaceuticals for removal of solvents by sublimation. Key performance characteristics of a freezedryer condenser are largely dependent on the vapor and ice dynamics in the low-pressure environment. The main objective of this work is to develop a modeling and computational framework ...

2009
Ali Kahraman Alaeddin Çelebi

In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 °C, 30 °C and 40 °C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator an...

2008
P Shao S T Jiang Y K Ye

Balanced equations of a binary mixture for molecular distillation (MD) were derived on the basis of relation of heat and mass transfer in liquid films on both the evaporating and condensing surface. Effects of feed temperature and condenser temperature on film thickness, film surface temperature and concentration, degree of evaporation and concentration of distillate were analyzed for MD. The l...

1999
P.-C. Hsu C. H. Mastrangelo K. D. Wise

This paper presents the analysis, design, fabrication, and testing of a condenser microphone utilizing a thin low-stress polycrystalline silicon diaphragm suspended above a p+ perforated back plate. The microphone is fabricated using a combination of surface and bulk micromachining techniques in a single wafer process without the need of wafer bonding. The device shows sensitivities of -34 dB (...

Journal: :CoRR 2014
Pedro Camelo João Moura Ludwig Krippahl

Botnets represent a global problem and are responsible for causing large financial and operational damage to their victims. They are implemented with evasion in mind, and aim at hiding their architecture and authors, making them difficult to detect in general. These kinds of networks are mainly used for identity theft, virtual extortion, spam campaigns and malware dissemination. Botnets have a ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید