نتایج جستجو برای: lung imrt

تعداد نتایج: 312673  

2012
RYAN L. SMITH AMIT SAWANT LAKSHMI SANTANAM RAGHU B. VENKAT LAURENCE J. NEWELL BYUNG-CHUL CHO HERBERT CATELL PAUL J. KEALL PARAG J. PARIKH

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, threedimensional position tracking system (Calypso 4D Localization System)...

Journal: :basic and clinical cancer research 0
kaveh shirani tak abi department of engendering, science and research branch, islamic azad university, tehran, iran hassan ali nedaie department of medical physics, tehran university of medical science, tehran, iran. hossein hassani department of engendering, science and research branch, islamic azad university, tehran, iran mansour naderi m.sc of medical physics, radiotherapeutic oncology department of cancer institute mohammad babaie radiotherapy oncology department, cancer institute, tehran university of medical science, theran, iran mahmood samei radiotherapeutic oncology, radiation oncology center of karaj, iran

the aim of radiation therapy treatment planning is to achieve an optimal balance between delivering a high dose to target volume and a low dose to healthy tissues. in order to refrain any complications resulting from the dose to the surrounding normal organs, the role of treatment plan has been critically evaluated in term of how large the volume or mass of normal tissues exposed in the radiati...

Journal: :Tumori 2010
Savino Cilla Cinzia Digesú Giovanni Silvano Gabriella Macchia Mariangela Massaccesi Francesco Deodato Gilbert D A Padula Andrea Fidanzio Angelo Piermattei Alessio G Morganti

A 77-year-old male patient with unresected malignant pleural mesothelioma, clinical stage T3N0M0 according to the New International Staging System for Diffuse Malignant Pleural Mesothelioma, received intensity-modulated radiotherapy (IMRT) with a simultaneous integrated boost (SIB) after 6 cycles of chemotherapy with cisplatin and pemetrexed. SIB-IMRT delivered 40.5 Gy (1.5 Gy/fraction) to the ...

Journal: :Acta oncologica 2013
Rovel J Colaco Soon Huh Romaine C Nichols Christopher G Morris Harry D'Agostino Stella Flampouri Zuofeng Li Dat C Pham Abubakr A Bajwa Bradford S Hoppe

BACKGROUND Concurrent chemoradiotherapy (CRT) is the standard of care in patients with limited-stage small cell lung cancer (SCLC). Treatment with conventional x-ray therapy (XRT) is associated with high toxicity rates, particularly acute grade 3+ esophagitis and pneumonitis. We present outcomes for the first known series of limited-stage SCLC patients treated with proton therapy and a dosimetr...

2012
Stephanie LA Govaert Esther GC Troost Olga CJ Schuurbiers Lioe-Fee de Geus-Oei Ariën Termeer Paul N Span Johan Bussink

PURPOSE The aim of this retrospective cohort study was to assess treatment outcome, and acute pulmonary and esophageal toxicity using intensity modulated (sequential/concurrent chemo)radiotherapy (IMRT) in locally advanced stage III non-small cell lung cancer (NSCLC). METHODS AND MATERIALS Eighty-six patients with advanced stage NSCLC, treated with either IMRT only (66 Gy) or combined with (s...

2015
Mark A D’Andrea G Kesava Reddy

Malignant thymomas are rare epithelial neoplasms of the anterior superior mediastinum that are typically invasive in nature and have a higher risk of relapse that may ultimately lead to death. Here we report a case of an advanced malignant thymoma that was successfully treated with neoadjuvant chemotherapy followed by surgical resection and subsequently with advanced and novel radiation therapy...

2017
Yuan-Gui Chen An-Chuan Li Wen-Yao Li Miao-Yun Huang Xiao-Bo Li Ming-Qiu Chen Mutian Zhang Ben-Hua Xu

Journal of Medical Physics ¦ Volume 42 ¦ Issue 2 ¦ April-June 2017 100 We highly appreciate your comments. It is well known that there are considerable target position uncertainties during breast radiotherapy. These uncertainties result from respiratory motions, tissue and organ deformation, daily patient setup, and other causes. Respiratory gating and breath control can reduce the target posit...

2004
James L. Bedford Peter J. Childs Alan P. Warrington

With intensity-modulated radiotherapy (IMRT), it is important that the inverse planning process yields the most appropriate dose distribution for the patient and that the delivered dose then corresponds to the planned dose. This paper presents methods by which the inverse planning and delivery of segmental (step-and-shoot) IMRT can be verified, and gives results for a typical treatment planning...

Journal: :International journal of radiation oncology, biology, physics 2010
Alan B Coon Adam Dickler Michael C Kirk Yixiang Liao Anand P Shah Jonathan B Strauss Sea Chen Julius Turian Katherine L Griem

PURPOSE For patients with left-sided breast cancers, radiation treatment to the intact breast results in high doses to significant volumes of the heart, increasing the risk of cardiac morbidity, particularly in women with unfavorable cardiac anatomy. We compare helical tomotherapy (TOMO) and inverse planned intensity modulated radiation therapy (IMRT) with three-dimensional conformal radiothera...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید