نتایج جستجو برای: ionization detector

تعداد نتایج: 95146  

Journal: :Physics in medicine and biology 2015
D Poppinga J Meyners B Delfs A Muru D Harder B Poppe H K Looe

This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diame...

2003
L. De Nardo V. Conte P. Colautti W. Y. Baek B. Grosswendt G. Tornielli

The electron collector is a system of electrodes that encloses an almost wall-less cylindrical volume whose height equals its diameter of 3.7 mm (SV). The α-particles of a collimated narrow beam pass at a distance “d” from the sensitive volume (SV) and are detected by a solid-state detector (SSD); the low-energy secondary electrons produced by each α-particle within the SV are collected to a si...

2013
T. Bryś R. Eykens F.-J. Hambsch A. Moens S. Oberstedt C. Pretel G. Sibbens D. Vanleeuw M. Vidali

Fast spectrum neutron-induced fission cross sections of transuranic isotopes are being of special demand in order to provide accurate data for the new GEN-IV nuclear power plants. To minimize the uncertainties on these measurements accurate data on spontaneous fission half-lives and detector efficiencies are a key point. High -active actinides need special attention since the misinterpretation ...

2008
M. Gai R. Alon A. Breskin M. Cortesi D. N. McKinsey J. Miyamoto K. Ni D. A. R. Rubin T. Wongjirad

The Yale-Weizmann collaboration aims to develop a lowradioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from ...

Journal: :Medical physics 2012
I Ciancaglioni Marco Marinelli E Milani G Prestopino C Verona G Verona-Rinati R Consorti A Petrucci F De Notaristefani

PURPOSE To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherap...

The zinc-cadmium oxide (ZnO-CdO) nanocomposites with different weight percentages of cadmium oxide (CdO) nanoparticles were successfully synthesized by the sonochemical method using zinc and cadmium nitrates as precursors to probe their nano-structured surfaces for the decomposition reactions of chloroethyl phenyl sulfide (CEPS) as a surrogate of sulfur mustard agent simulant. Scanning electron...

2001
A. Morales

One IGEX Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. A new exclusion plot, σ(m), has been derived for WIMP-nucleon spin-independent interactions. To obtain this result, 40 days of data from the IGEX detector (energy threshold Ethr ∼ 4 keV), re...

Journal: :Journal of Instrumentation 2023

Abstract Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary increase sensitivity experiments light dark matter. Neutron capture on can be used produce with energies below 0.3 keV NR via asymmetric emission γ rays during de-excitation. The feasibility an measurement using neutron was investigated for Michigan Xenon...

Journal: :international journal of bio-inorganic hybrid nanomaterials 0

the zinc-cadmium oxide (zno-cdo) nanocomposites with different weight percentages of cadmium oxide (cdo) nanoparticles were successfully synthesized by the sonochemical method using zinc and cadmium nitrates as precursors to probe their nano-structured surfaces for the decomposition reactions of chloroethyl phenyl sulfide (ceps) as a surrogate of sulfur mustard agent simulant. scanning electron...

Kourosh Arbabi, Zahra Saberi

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید