نتایج جستجو برای: intercrystal scatter

تعداد نتایج: 12386  

Journal: :The Journal of animal ecology 2016
Zhishu Xiao Zhibin Zhang

It is well known that direct effects of seed predators or dispersers can have strong effects on seedling establishment. However, we have limited knowledge about the indirect species interactions between seeds of different species that are mediated by shared seed predators and/or dispersers and their consequences for plant demography and diversity. Because scatter-hoarding rodents as seed disper...

2015
Peter G.F. Watson Ernesto Mainegra‐Hing Nada Tomic Jan Seuntjens

Cone-beam computed tomography (CBCT) images suffer from poor image quality, in a large part due to contamination from scattered X-rays. In this work, a Monte Carlo (MC)-based iterative scatter correction algorithm was implemented on measured phantom data acquired from a clinical on-board CBCT scanner. An efficient EGSnrc user code (egs_cbct) was used to transport photons through an uncorrected ...

2017
Mohammad Javad Tahmasebi Birgani Nahid Chegeni Mohammad Ali Behrooz Marziyeh Bagheri Amir Danyaei Azin Shamsi

INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...

2004
Songcan Chen Xubing Yang

Fisher linear discriminant analysis (FLDA) $nds a set of optimal discriminating vectors by maximizing Fisher criterion, i.e., the ratio of the between scatter to the within scatter. One of its major disadvantages is that the number of its discriminating vectors capable to be found is bounded from above by C-1 for C-class problem. In this paper for binary-class problem, we propose alternative FL...

Journal: :Medical physics 2015
G J Bootsma F Verhaegen D A Jaffray

PURPOSE X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). METHO...

Journal: :Journal of biomedical optics 2010
Robert M Pasternack Jing-Yi Zheng Nada N Boustany

We combine optical scatter imaging (OSI) with fluorescence imaging of mitochondria to investigate the spatial relationship between the optical scatter signal and the location and structure of mitochondria within endothelial cells undergoing apoptosis. The OSI data corroborate our previous results showing a decrease in the intensity ratio of wide-to-narrow angle scatter [optical scatter image ra...

2010
Toshiki Hanyu

This paper describes the development of a theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls. The concepts of equivalent scattering area, equivalent scatter reflection area, average scattering coefficient and average scatter reflection coefficient are introduced in order to express all walls' capabili...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید