The warming and humidification of inspired gases for ventilated neonates are routine. There are no data on the temperature of the gasat the airway opening in ventilated neonates. Is the inspired gas temperature at the airway opening, as expected and set on the humidifier, around 378C?We aimed to measure temperature at the airway opening and compare this with the circuit temperature. This was an...
BACKGROUND Over a few months in the spring of 2011, a cluster of patients with severe respiratory distress were admitted to our intensive care unit (ICU). Household clustering was also observed. Extensive laboratory investigations failed to detect an infectious cause. METHODS Clinical, radiological and pathological investigations were conducted and the Korean Center for Disease Control perfor...
BACKGROUNDS An outbreak of lung injury among South Korean adults was examined in a hospital-based case-control study, and the suspected cause was exposure to humidifier disinfectant (HD). However, a case-control study with community-dwelling controls was needed to validate the previous study's findings, and to confirm the exposure-response relationship between HD and lung injury. METHODS Each...
Antimicrobial capsules were evaluated for their effectiveness to control bacterial contamination of cool mist humidifiers. These capsules contain a mixture of silver and copper promoted alumina beads designed to release low concentrations of these oligodynamic metals into the reservoir water for bacteria control. The reservoir water and mist droplets from the humidifier units were tested for th...
BACKGROUND This study was performed to determine the effects of a humidifier with heated wire circuits on the incidence and severity of postoperative sore throat (POST) and cough after thyroidectomy. METHODS A total of 61 patients scheduled for elective thyroid surgery under general anesthesia were included in this prospective study. We randomized the patients in to two groups, "without activ...
During noninvasive ventilation (NIV) for acute respiratory failure, the patient's comfort may be less important than the efficacy of the treatment. However, mask fit and care are needed to prevent skin damage and air leaks that can dramatically reduce patient tolerance and the efficacy of NIV. Choice of interface is a major determinant of NIV success or failure. The number and types of NIV inte...
BACKGROUND In-line administration of bronchodilators is widely used in pediatric patients receiving mechanical ventilation. We compared the amount of albuterol captured at the end of the endotracheal tube (ETT) with an intrapulmonary percussive ventilator (IPV) versus a Salter 8900 jet nebulizer placed in-line in a pediatric ventilator model, under various operating conditions. We hypothesized ...