نتایج جستجو برای: forgo type heat exchanger

تعداد نتایج: 1532348  

2014
Khaled Hassan Saleh Omar Abdelaziz Vikrant Aute Reinhard Radermacher Shapour Azarm Khaled SALEH Omar ABDELAZIZ Vikrant AUTE Reinhard RADERMACHER

The objective of this paper is to evaluate and optimize the performance of 1 kW integrated heat exchanger module for new generations of air cooled heat exchangers. The first objective is to minimize the ratio of the header frontal area to the entire heat exchanger frontal which will help to reduce the header size. The second objective is to minimize the pressure drop for the entire heat exchang...

2014
Mustapha Ait Lafkih

In industrial environments, the heat exchanger is a necessary component to any strategy of energy conversion. Much of thermal energy used in industrial processes passes at least one times by a heat exchanger, and methods systems recovering thermal energy. This survey paper tries to presents in a systemic way an sample control of a heat exchanger by comparison between three controllers LQR (line...

Journal: :international journal of nano dimension 0
r. aghayari young researchers and elite club, shahrood branch, islamic azad university, shahrood, iran h. maddah department of chemistry, sciences faculty, arak branch, islamic azad university, arak, iran j. baghbani arani department of chemical engineering, faculty of engineering, arak university, arak, iran h. mohammadiun assistant professor, department of mechanical engineering, shahrood branch, islamic azad university, shahrood, iran e. nikpanje department of chemistry, sciences faculty, north tehran branch, islamic azad university, north tehran, iran.

one way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. in the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. in this work, the performance of water / iron oxide nanofluid in a double...

2014
Udumula Suresh K.Ramkumar G.Balasubramanian S.Rakesh Kumar

Temperature of fluid stream through tube is a key variable in shell and tube heat exchanger. However, this variable is not easy to measure straightly. Therefore, a state observer is designed to estimate the tube temperature variable for direct control of shell and tube heat exchanger. A dynamical state space model is used to describe the heat exchanger process. Kalman filter based observer is d...

2017
Wenjing Ding

Abstract—Liquid spray heat exchanger is the critical equipment of temperature regulating system by gaseous nitrogen which realizes the environment temperature in the range of -180 °C~+180 °C. Liquid nitrogen is atomized into smaller liquid drops through liquid nitrogen sprayer and then contacts with gaseous nitrogen to be cooled. By adjusting the pressure of liquid nitrogen and gaseous nitrogen...

2016
Toufik Bentaleb Minh Tu Pham Damien Eberard Wilfrid Marquis-Favre

This paper presents a Bond Graph (BG) modelling approach to add and exploit on existing Modelica models some information on the energy structure of the systems. The developed models in the ThermosysPro library (Modelica-based) are already validated against the experimental data in previous works. A plate heat exchanger (PHE), which is equipment for nuclear power plants, is considered as a case ...

2010
Milan Visaria Issam Mudawar Timothée Pourpoint

0017-9310/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.ijheatmasstransfer.2010.09.029 ⇑ Corresponding author. Tel.: +1 765 494 5705; fax E-mail address: [email protected] (I. Mud This study explores the use of a high-pressure metal hydride (HPMH), Ti1.1CrMn, to store hydrogen at high pressures (up to 310 bar) and temperatures below 60 C, conditions that are suitable for automobile...

2013
Dr John White

The performance of the adsorption cooling system is assessed in terms of the heat transfer coefficients of adsorbent bed heat exchanger. These parameters in-turn determine the specific cooling capacity (SCC) and the coefficient of the performance (COP) of the adsorption cooling system. It was observed that the overall heat transfer coefficients of the heat exchanger have a direct linear relatio...

2014
Q. S. Yuan

Q. s. Yuan Electricite de France centre des Renardieres Departement Application de l'Electricite 77250 Moret sur Laing, France Noncondensable gases in a condenser will reduce the heat transfer coefficient and this is the case of the mixture (steam + air) j Rll4 heat exchanger in our high temperature heat pump. This heat exchanger is a shell tube type and is for the purpose of simulating industr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید