A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulat...
of high attenuation. The prosthetic lens is also thinner, only about 12 mm thick. It is otherwise in the same anatomic position and orientation as a native lens. These characteristic CT features of an intraocular lens prosthesis readily distinguish it from most diseases of the intraocular lens or a traumatically introduced foreign body within the anterior chamber. It is theoretically possible t...
BACKGROUND Splitting of the lens capsule with a double-ring contour during continuous curvilinear capsulorrhexis has not often been reported. CASE An 86-year-old woman underwent phacoemulsification cataract extraction with intraocular lens implantation in the right eye. Preoperatively, the anterior lens capsule appeared normal. OBSERVATIONS A double-ring sign was observed during capsulorrhe...
Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...
Cataract surgery is a technique described since recorded history, yet it has greatly evolved only in the latter half of the past century. The development of the intraocular lens and phacoemulsification as a technique for cataract removal could be considered as the two most significant strides that have been made in this surgical field. This review takes a comprehensive look at all aspects of ca...
The Strampelli anterior chamber intraocular lens was created in 1953, and was primarily used to treat myopia and aphakia. Due to the positioning of the lens, it was associated with a number of complications, and was later modified to decrease the rate of significant complications, including endothelial cell loss. This paper describes a 62-year-old man, who has had a Strampelli intraocular lens ...
BACKGROUND The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. METHODS A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens ...
PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...
Purpose: To describe a new intraocular lens that can be implanted in case of rupture of the posterior capsule and lack of capsular support. Methods: This experimental study was carried out on ten Flanders rabbits. The right eye of each rabbit underwent intra capsular lens extraction and two peripheral iridectomies, and the new lens was implanted with an optic rest in the posterior chamber. Addi...