نتایج جستجو برای: electron capture detector
تعداد نتایج: 476704 فیلتر نتایج به سال:
in this research, the chloroform (chcl3) removal effectiveness of two water treatment systems including membrane technology and granular activated carbon (gac) adsorption were studied. two bench-scales were designed and set up: 1) nanofiltration (nf) spiral-wound modules and 2) gac adsorption column. chloroform was considered as trihalomethanes (thms) basic indicator compound. the inlet and out...
This experiment was undertaken to investigate whether the half life of the electron capture decay of Ru in a metallic environment shows any temperature dependence, as has been claimed recently for the electron capture decay of Be [1]. Previous publications claiming to observe a temperature dependence of β-decay half-lives [1 3] in a metallic environment have used the so-called “Debye effect” to...
Recently, we demonstrated that a radio-frequency-free electromagnetostatic (rf-free EMS) cell could be retrofitted into a triple quad mass spectrometer to allow electron-capture dissociation (ECD) without the aid of cooling gas or phase-specific electron injection into the cell (Voinov et al., Rapid Commun Mass Spectrom 22, 3087-3088, 2008; Voinov et al., Anal Chem 81, 1238-1243, 2009). Subsequ...
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays role in geochronological dating techniques. branching ratio of the electron capture directly to ground state argon-40 has never been measured, which can cause difficulty...
In this study, the detection of alpha particles in the high current mode is investigated in the presence of two gaseous electron multipliers in the micro-pattern structures. Thick Gas Electron Multiplier (TGEM) and an Electron Multiplier Assemblies (EMA) were designed and constructed as amplification gap in the detector chamber. An ion chamber is employed to measure the current of interaction b...
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید